● APPENDICES
RA RF ATTENUATOR
Sets or reads RF ATT(attenuator).
1
2
3 4 5 6 7 8 9 10 11 12 13 14
R A
P1
;
1 2 3
4 5 6 7 8 9 10 11 12 13 14
R A
;
1 2 3 4 5 6 7 8 9 10 11 12 13 14
R A
P1
;
RC
RIT CLEAR
Sets the RIT frequency shift to 0.
1
2
3 4 5 6 7 8 9 10 11 12 13 14
R
C
;
1 2 3
4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
RD
RU RIT DOWN/UP
Lowers/raises RIT frequency.
1
2
3 4 5 6 7 8 9 10 11 12 13 14
R
D/U
;
1 2 3
4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
RG RF GAIN
Sets or reads RF gain.
1
2
3 4 5 6 7 8 9 10 11 12 13 14
R G
P1
;
1 2 3
4 5 6 7 8 9 10 11 12 13 14
R G
;
1 2 3 4 5 6 7 8 9 10 11 12 13 14
P1
R G
;
RM READ METER
Selects a meter function or reads meter values.
1
2
3 4 5 6 7 8 9 10 11 12 13 14
R M
P1
;
1 2 3
4 5 6 7 8 9 10 11 12 13 14
R M ;
1 2 3 4 5 6 7 8 9 10 11 12 13 14
R M P1
P2
;
94
RT RIT
Parameter Format
Parameter function
Sets RIT OFF/ON or reads status.
P1
48
ATTENUATOR
RX
Parameter Format
Parameter function
Note:
This command also clears the XIT
frequency (same as RIT shift).
The command functions independently
from the RIT/XIT control.
SC SCAN
Parameter Format
Parameter function
Note:
This command also affects the XIT
frequency (same as RIT shift).
The command functions independently
from the RIT/XIT control.
SD SEMI BREAK-IN DELAY TIME
Parameter Format
Parameter function
Sets or reads Semi Break-in delay time.
P1
31
RF GAIN
SM S-METER
Parameter Format
Parameter function
METER SWITCH
P1
24
METER VALUE
P2
22
1
2
3 4 5 6 7 8 9 10 11 12 13 14
R T P1
;
1 2 3
4 5 6 7 8 9 10 11 12 13 14
R T
;
1 2 3 4 5 6 7 8 9 10 11 12 13 14
R T P1 ;
TX RX, TX
Selects receive/transmit mode.
1
2
3 4 5 6 7 8 9 10 11 12 13 14
RX/TX
;
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
RX/TX
;
Sets Scan OFF/ON or reads status.
1
2
3
4
5
6
7
8
9 10 11 12 13 14
S C P1
;
1
2
3
4
5
6
7
8
9 10 11 12 13 14
S C
;
1
2
3
4
5
6
7
8
9 10 11 12 13 14
S C P1 ;
1
2
3 4 5 6 7 8 9 10 11 12 13 14
S D
P1
;
1 2 3
4 5 6 7 8 9 10 11 12 13 14
S D
;
1 2 3 4 5 6 7 8 9 10 11 12 13 14
S D
P1
;
S-meter and TX RF meter readings.
1
2
3
4
5
6
7
8
9 10 11 12 13 14
1
2
3
4
5
6
7
8
9 10 11 12 13 14
S M
;
1
2
3
4
5
6
7
8
9 10 11 12 13 14
;
S M
P1
Parameter Format
Parameter function
P1
1
RIT OFF/ON
Parameter Format
Parameter function
Parameter Format
Parameter function
P1
1
SCAN OFF/ON
Parameter Format
Parameter function
P1
49
SEMI BREAK-IN
DELAY TIME
Parameter Format
Parameter function
P1
22
S-METER
VALUE

Advertisement