Pioneer PDP-LX5080D Service Manual page 128

Table of Contents

Advertisement

1
Recovery flowchart (1-1)...Changing the VOL OFFSET setting voltage
A
[From the Main flowchart (1)]
RST MASK 12 (Light blue)
Gradually increase the VOL OFFSET value until disappear the
discharge (lit cell).
The VOL OFFSET value must be 133 or less.
B
Current VOL OFFSET > 133?
Display RST MASK 10 (Pink). / [MKS S60]
[To the Recovery flowchart (1-2)]
C
Recovery flowchart (1-2)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) / Recovery flowchart (1-1)]
RST MASK 10 (Pink)
D
Gradually increase the VOL OFFSET value until disappear the
discharge (lit cell).
The VOL OFFSET value must be 133 or less.
Current VOL OFFSET > 133?
E
Display RST MASK 02 (Red). / [MKS S52]
Set VOL OFFSET to the current setting value plus 112. / [VOF ***]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
F
128
1
2
No
No
No
A
PDP-LX5080D
2
3
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
Yes
Replacement of abnormal circuits or
re-replacement of the panel required
3
4
4