Pioneer PDP-LX5080D Service Manual page 126

Table of Contents

Advertisement

1
Main flowchart (1)...Checking VOL OFFSET
A
[From Preparation]
Display RST MASK 12 (Light blue). / [MKS S62]
Set VOL OFFSET to the tentative setting value minus 64. / [VOF ∗∗∗]
B
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 10 (Pink). / [MKS S60]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
C
Display RST MASK 02 (Red). / [MKS S52]
Set VOL OFFSET to the tentative setting value plus 48. / [VOF ∗∗∗]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
D
Display RST MASK 03 (Green). / [MKS S53]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
E
Return VOL OFFSET to the tentative setting value. / [VOF ∗∗∗]
Determine the tentative setting value for VOL OFFSET as
the final value.
[To the Main flowchart (2)]
F
126
1
2
Yes
No
Yes
No
Yes
No
Yes
No
PDP-LX5080D
2
3
To the Recovery flowchart (1-1)
To the Recovery flowchart (1-2)
To the Recovery flowchart (1-3)
To the Recovery flowchart (1-4)
From the Recovery flowchart (1-2) and (1-4)
3
4