Pioneer PDP-LX5080D Service Manual page 124

Table of Contents

Advertisement

1
Overview
A
Preparation
Clearing of the hour meter and pulse meter
Aging with RST MASK 01 (White) displayed
Main flowchart (1)
(VOL OFFSET check)
Checking VOL OFFSET (min)
(RST MASK 12: Light blue)
B
OK
Checking VOL OFFSET (min)
(RST MASK 10: Pink)
OK
Checking VOL OFFSET (max)
(RST MASK 02: Red)
OK
Checking VOL OFFSET (max)
(RST MASK 03: Green)
OK
C
Main flowchart (2)
(VOL YNOFS check)
Checking VOL YNOFS3/4/1 (min)
(RST MASK 16: Green 1023+)
OK
D
Checking VOL YNOFS3/4/1 (min)
(RST MASK 15: Red 1023+)
OK
Checking VOL YNOFS3/4/1 (max)
(RST MASK 22: Cyan 3SF)
OK
E
Adjustment completed
Replacement with the parts
for service
• Re-replacement of the panel
F
• Replacement of the DRIVE Assy
124
1
2
Recovery flowchart (1)
(Changing the VOL OFFSET setting voltage)
(1-1)
Checking VOL OFFSET (min)
(RST MASK 12: Light blue)
OK
(1-2)
Checking VOL OFFSET (min)
(RST MASK 10: Pink)
OK
Checking VOL OFFSET (max)
(RST MASK 02: Red)
OK
Checking VOL OFFSET (max)
NG
(RST MASK 03: Green)
OK
NG
Recovery flowchart (1)
(Changing the VOL OFFSET setting voltage)
(1-3)
NG
Checking VOL OFFSET (max)
(RST MASK 02: Red)
OK
(1-4)
NG
Checking VOL OFFSET (max)
(RST MASK 03: Green)
OK
Checking VOL OFFSET (min)
(RST MASK 12: Light blue)
OK
Checking VOL OFFSET (min)
(RST MASK 10: Pink)
OK
Recovery flowchart (2)
(Changing the VOL YNOFS setting voltage)
(2-1)
NG
Checking VOL YNOFS3/4/1 (min)
(RST MASK 16: Green 1023+)
OK
NG
Checking VOL YNOFS3/4/1 (min)
(RST MASK 15: Red 1023+)
NG
OK
NG
Checking VOL YNOFS3/4/1 (max)
(RST MASK 22: Cyan 3SF)
OK
Recovery flowchart (2)
(Changing the VOL YNOFS setting voltage)
(2-2)
Checking VOL YNOFS3/4/1 (min)
(RST MASK 15: Red 1023+)
OK
Recovery flowchart (2)
(Changing the VOL YNOFS setting voltage)
(2-3)
Checking VOL YNOFS3/4/1 (max)
(RST MASK 22: Cyan 3SF)
OK
Checking VOL YNOFS3/4/1 (min)
(RST MASK 16: Green 1023+)
OK
Checking VOL YNOFS3/4/1 (min)
(RST MASK 15: Red 1023+)
OK
PDP-LX5080D
2
3
NG
Note on voltage calculation
When calculating the setting voltage, round off to
NG
get rid of the fractional part.
Range of margin measuring
NG
Read the voltage within the hysteresis (stricter
value).
NG
V
Erroneous discharge
Read the voltage
within this range.
NG
Erroneous discharge
NG
Definition of limits for the voltage margins
NG
(abnormal lit/dead cells)
Abnormal lit cells:
NG
• Five or fewer abnormal cells on the whole screen
• Two or fewer abnormal cells within a radius of 1 cm
Abnormal dead cells
• Fifteen or fewer abnormal cells on the whole screen
• Two or fewer abnormal cells within a radius of 1 cm
∗: Abnormal cells visually recognizable at a distance of
NG
1 meter from the panel must be counted.
∗: Cells displayed abnormally for less than one second
are not counted as abnormal cells.
NG
Definition of tones for the measuring
signals
FHD signal (1920*1080)/Video 60-Hz sequence
/Dither: ON, L dither: ON, noise: OFF
White
RST MASK 01 (R 1023 /G 1023 /B 1023)
Red
RST MASK 02 (R 1023 /G 0 /B 0)
NG
Green
RST MASK 03 (R 0 /G 1023 /B 0)
Pink
RST MASK 10 (R 1023 /G 626 /B 1023)
Light blue
RST MASK 12 (R 626 /G 1023 /B 1023)
Red 1023+
RST MASK 15 (R 1023 /G 120 /B 120)
Green 1023+
RST MASK 16 (R 120 /G 1023 /B 120)
Cyan 3SF
RST MASK 22 (R 0 /G 169 /B 169)
NG
NG
NG
3
4
Adjustment
value m+1
Adjustment
value m
No erroneous
discharge
Adjustment
value n
Adjustment
value n-1
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-lx508d

Table of Contents