Seen IRIS 860 Sensor Installation Manual

Seen IRIS 860 Sensor Installation Manual

Hide thumbs Also See for IRIS 860 Sensor:

Advertisement

Quick Links

INSTALLATION GUIDE
SEEN IRIS 860 Sensor
SEEN IRIS 860 Cab Box
we've Got Your Back
www.seensafety.com |
1
© Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IRIS 860 Sensor and is the answer not in the manual?

Questions and answers

Summary of Contents for Seen IRIS 860 Sensor

  • Page 1 INSTALLATION GUIDE SEEN IRIS 860 Sensor SEEN IRIS 860 Cab Box we’ve Got Your Back www.seensafety.com | © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 2: Table Of Contents

    IRIS 860 sensors and Cab Boxes require a 12–24 +64 4 381 4475 volt power supply. Power supplies exceeding www.seensafety.com 24 volts require a DC/DC voltage converter. support@seensafety.com © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 3: Before You Start

    Power supplies exceeding 24 volts require a DC/DC voltage converter. IRIS 860 sensor Buzzer Vent Accessory Power socket socket Laser M6 mount transmit M6 mount Front Side Back © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 4: Power Requirements

    WARNING. If another accessory sharing the DC/ DC converter requires an isolation barrier for safety, use a separate DC/DC converter for the IRIS 860 sensor. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 5: Sensor Mounting

    • Consider a Top Mount instead of an Underneath Mount. • Set the sensor to Reduced Volume in the IRIS 860 setup app. • Use SEEN’s snap-on volume reduction cap accessory. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 6: Sensor Wiring

    By default IRIS 860 sensors are pre-set so they can only alert if they are receiving a direction signal (usually reverse) from the machine. This direction dependent setting can be changed in the IRIS 860 setup app. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 7: Cab Box Wiring

    Box. These cables are available in 5m, 10m, or 15m lengths. Cab Box Sensor Cable Cab Box IRIS 860 sensor Cab Box Cab Box Cab Box Sensor Cable Power Cable © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 8 (usually reverse) from the machine via the Cab Box. This direction dependent setting can be changed in the IRIS 860 setup app. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 9: Cab Box Sensor Cable

    (Attach to Cab Box) Screw-block 1. Brown 4. Black 16mm Other wires Cable Grey wire (centre) 5. Grey (Centre) 8mm 9mm 3. Blue 2. White Wire stripping guide Re-wireable plug © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 10: Weather Shield

    Screw A Screw A Step 3 Insert screw B on both sides. Check the alignment and evenly tighten the four M6 mounting screws to maximum 10Nm. Screw B © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 11: Set-Up Examples

    Pre-alert = beeping audible alert A customised detection zone can help to minimise non-critical detections Note. The scenarios shown above are examples only. Your specific requirements may differ. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 12 CHECK. In either option, when angled correctly both sensors should simultaneously detect a person standing in the center of the detection zone at the maximum and minimum detection range. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 13: Internal Self Check Function

    Remove dust and dirt using clean water and a clean non- abrasive cloth. Do not use high pressure water jets to clean. Do not use chemical cleaners including alcohol, benzene, thinners, and degreasers. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 14: Trouble-Shooting

    6. The sensor is beeping and flashing and the sequence is NOT long-short-short, long-short-short Cause: Internal fault detected. Solution: There are no user serviceable parts. Contact your supplier for repair or replacement. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 15 If the vehicle is in reverse and the voltage is not 3-100V between the ground pin (–) and the reverse direction pin, there may be a grounding issue. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 16: Connecting An Accessory

    The IRIS 860 Accessory Cable (P/n SI-121) can be used to connect a third-party accessory such as a camera, data- logger, light etc. IMPORTANT. Do not attach the Accessory Cable to a Cab Box. The Accessory Cable is for the IRIS 860 sensor only. Pin no. Wire colour Description...
  • Page 17 Detection NPN (BLUE) Ground 12V power supply Detection 3V6 (BLACK) Output high Do not connect (GREY) during detection 12V trigger input Detection 12V (PINK) Logic buffer 12V camera © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 18: Changing The Sensor Settings

    • Some OTG compatible smart phones and tablets will not supply sufficient power to the sensor • Check your device can connect to an IRIS 860 sensor BEFORE going on site. Note. SEEN have tested and recommend the LENOVO Tab M8 HD P/n TB-8505F tablet it to provide reliable connection.
  • Page 19 Direct to sensor • Launch the SEEN IRIS 860 setup app • Connect the IRIS 860 sensor to the computer or Android mobile device using an IRIS 860 USB Config Cable (OTG compatible smart phones or tablets will require a USB OTG adapter) •...
  • Page 20: Software Settings

    While Test Mode is active, when the operator engages the Direction Dependent Alert gear, the audible alert should sound indicating that the direction signal is correctly connected. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 21: Warranty

    (including alcohol, benzene, thinners, and degreasers), or incorrect electrical connection. There are no user serviceable parts. Opening the enclosure will void the warranty. © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 22: Specifications

    -20 to +60 degrees C ambient Product specifications are subject to change without notice to improve reliability, function, design or otherwise. SI860-0000 SI860-1119 SN-A0-0000 SN-A01000 Cab Box label Sensor label © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 23 Do not connect Detection High Output 11v max. Supply voltage 12v, 2K 470 Ohm resistor voltage logic Ohm load to ground internally in series 9.3v min. detection with this output © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 24 PNP output. The reverse to Iris sensor / output line gets pulled Iris-I camera up to the supply voltage when Reverse in (M12 4-pin pin 3) is high © Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3...
  • Page 25 IMPORTANT. SEEN IRIS 860 sensors can provide collision warning assistance to the operator but do not replace the need for proper operator training and best practice safe operating procedure. While IRIS 860 sensors can alert the machine operator to a potential collision, the operator is always fully responsible for the safe operation of the equipment.
  • Page 26 www.seensafety.com | we’ve Got Your Back...

This manual is also suitable for:

Iris 860 cab boxIris 860