Download Print this page

User' Troubleshooting - Vinotemp WINE-MATE WM-2500SSOWC Operation Care Installation Manual

Split water-cooled through-ceiling cooling system

Advertisement

This Troubleshooting Chart is not prepared to replace the training required for a
professional refrigeration service person, not is it comprehensive.
Complaint
1. Unit not running
2. Unit not
starting and
temperature
rising high
3.
Temperatur
e fluctuating
4. Temperature
high, unit
stopping
and starting
normally
5. Temperature
high, unit
stopping and
starting with
short
running
time
6.
Temperatur
e high or
not cooling
and running
continually
User's Troubleshooting
Possible Causes
a.
Power cord not plugged
b.
No power from supply
c.
Incorrect or loose wirings
d.
Low voltage
e.
Setting
higher
than
ambient temperature
f.
Waiting for cut-in
g.
Defrost light blinking
h.
Compressor light blinking
i.
Defective controller
a. Anti-short cycle
a. Air probe
a. Temperature setting high
a.
Air
probe
touching
evaporator
coil,
temperature ok
b.
Air probe in cold-air supply,
displaying temperature ok
c.
Failed controller and probe
a.
Improper cellar insulation &
seal
b.
Cellar too large
c.
Malfunctioning fans
d.
Evaporator airflow
a.
Check power cord
b.
Check receptacle and fuses
c.
Check all wirings and connections
d.
Contact an authorized electrician
e.
Lower temperature setting
f.
Wait
g.
Unit is under defrost mode
h.
Unit is under anti-short cycle delay
i.
Call service for diagnosis
a. Reset AC
a. When using an air probe, the wine bottle
temperature is mainly controlled by the
average air temperature. If the set-
point is 55°F with the differential 4F, the
cooling unit turns on at 59°F of air
temperature (It may be higher than
59°F if it is in anti-short cycle or defrost)
and turns off at 55°F of air temperature.
The average air temperature is 57°F,
and then the wine temperature is
around 57+/- 0.5°F. The air is light
enough to change so quickly that it
maintains relatively constant average
temperature that would prevent wine
bottle temperature from fluctuating.
a. Lower the setting
the
a.
Move the air probe away from the
displaying
evaporator
b.
Move the air probe away from the
cold-air supply
c.
Call service for diagnosis
a.
Check insulation, gasket and door
opening
b.
Check for excessive size
c.
Check for evaporator fans
d.
Check for air restrictions, air short-
circulation, grille directions
-11-
Response

Advertisement

loading

This manual is also suitable for:

Wine-mate wm-4500ssowc