■ WIRING(結線図)
(d): Hole of PCB Assy MAIN.
8
All manuals and user guides at all-guides.com
1. Processing method of Wiring Assy AC8 (WD350000)
   束線AC8(WD350000)の処理
(a): Top Cover
(a): Wirng Assy AC8
(a). Twist Wiring Assy AC8 three times, and fix to a top cover.
      束線AC8を3回捻り、トップカバーに固定します。
(b): PWB Print (reticulation)
(b). Adjust the position so that the wire is arranged within the range
of the PWB print (reticulation).
      線材が、基板印刷(網目)の範囲内に配置されるように位置を調
      整します。
(c): Filament Tape
(c): Hole of Screw tightening
(c). Fix the wire by pasting the filament tape to the position of figure.
      図の位置にフィラメントテープを貼り、線材を固定します。
*
Note that the wire (black) doesn't shut the hole that tightens the
screw.
      この時、線材(黒)が、ネジ締め穴を塞がないように注意して下さい。
2. Processing method of Wiring Assy USB10 (WG26710)
   束線USB10(WG26710)
(a)Hole of PCB Assy MAIN
(a). Wiring Assy USB10 is passed through the hole of PCB Assy MAIN.
      束線USB10をMAINシートの穴に通します。
(b)STYLE PIN
(b)C501,502,601,602
(b). Wiring Assy USB10 is fixed with the STYLE PIN that has placed
to the PCB Assy MAIN.
     束線USB10をMAINシート上のスタイルピンで固定します。
* Note that the wiring Assy USB10 doesn't approach C501,502,
601,602 of PCB Assy MAIN.
     この時、束線USB10がMAINシートのC501,502,601,602に近付
     かないように注意して下さい。
(c)CN101 of the PCB Assy USB
(c). Wiring Assy USB10 is connected with CN101 of the PCB Assy USB.
      束線USB10をUSBシートのCN101に接続します。
(d): Filament Tape
(d). Fix the wiring Assy USB10 by pasting the filament tape to the
position of figure.
      図の位置にフィラメントテープを貼り、束線USB10を固定します。
* Note that the wiring Assy USB10 doesn't shut the hole of PCB
Assy MAIN.
      この時、束線USB10がMAINシートの穴を塞がないように注意
      して下さい。
*1: This connector assembly is not a service parts.
(この束線はサービスパーツ部品ではありません。)
*1
の処理
*1