Joint Cementing Procedure - COMFORT-AIRE Century GDD95C Series Service Manual

Hide thumbs Also See for Century GDD95C Series:
Table of Contents

Advertisement

Outdoor Exhaust
Vent Pipe
Capacity
Dia.
(in.)
1-1/2
1
2
045
2-1/2
3
1-1/2
1
2
070
2-1/2
3
2
090
2-1/2
3
2
110
2-1/2
3
2 inch to 1-1/2 inch reducer required, must be field provided.
1
* Requires field-provided and installed 1-1/2" exhaust accelerator.
** Kit 51W11 is provided with a 1-1/2" accelerator, which must be used for all 45,000 and 70,000 furnace installations. When using
1-/2 in. piping, the pipe must be transitioned to 2 in. pipe when used with the Flush Mount Kit.
† Termination kits 44W92, 44W93, 30G28 and 81J20 approved for use in Canadian installations to meet CSAB149.
†† The 44W92 concentric kit is provided with a 1-1/2" accelerator, which must be installed on the exhaust outlet when this kit is used
with the 45,000 and 70,000 furnaces. When using 1-1/2 in. piping, the pipe must be transitioned to 2 in. pipe when used with the
Concentric Kit.

Joint Cementing Procedure

All cementing of joints should be done according to the
specifications outlined in ASTM D 2855.
DANGER OF EXPLOSION!
Fumes from PVC glue may ignite during system check.
Allow fumes to dissipate for at least 5 minutes before
placing unit into operation.
1.
Measure and cut vent pipe to desired length.
2.
Debur and chamfer end of pipe, removing any ridges
or rough edges. If end is not chamfered, edge of pipe
may remove cement from fitting socket and result in a
leaking joint.
NOTE: Check the inside of vent pipe thoroughly for
any obstruction that may alter furnace operation.
Page 21 of 54
Standard
Outdoor Exhaust
Accelerator
Accelerator
(Dia. x Length)
(Dia. x Length)
1-1/2" x 12"
2" x 12"
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Table 9. Outdoor Termination Kits Usage
DANGER
1-1/2"
Flush-Mount
Concentric
Kit
71M80
51W11**
†44W92††
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
3.
Clean and dry surfaces to be joined.
4.
Test fit joint and mark depth of fitting on outside of pipe.
5.
Uniformly apply a liberal coat of PVC primer for PVC
or use a clean dry cloth for ABS to clean inside socket
surface of fitting and male end of pipe to depth of fitting
socket.
NOTE: Time is critical at this stage. Do not allow
primer to dry before applying cement.
6.
Promptly apply solvent cement to end of pipe and
inside socket surface of fitting. Cement should be
applied lightly but uniformly to inside of socket. Take
care to keep excess cement out of socket. Apply
second coat to end of pipe.
7.
Immediately after applying last coat of cement to pipe,
and while both inside socket surface and end of pipe
are wet with cement, forcefully insert end of pipe into
socket until it bottoms out. Turn PVC pipe 1/4 turn
Issue 2043
Concentric
2"
Concentric
Kit
Kit
69M29
or
or
†44W92††
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
3"
Concentric
Kit
60L46
or
44W93†
YES
YES
YES
YES
YES
YES
508115-01

Advertisement

Table of Contents
loading

Table of Contents