Download Print this page
Woods 59744 Programming Manual

Woods 59744 Programming Manual

Battery powered switch-mounted timer
Hide thumbs Also See for 59744:

Advertisement

Available languages

Available languages

Quick Links

R
Programming Manual for Model 59744 Battery Powered Switch-Mounted Timer
!
WARNING: TIMER IS INTENDED FOR INDOOR USE ONLY!
1.
Clock display
2.
Timer mode display
3.
Low battery indicator
4.
Memory erase (R) button
5.
Program button
6.
Set button
+ button
7.
8.
– button
9.
Battery door
10.
AM/PM display
11.
RCL-DST button
BEFORE PROGRAMMING THE TIMER: Timer requires two AA
!
batteries (not included). Batteries must be inserted before timer
can be programmed. Open battery door and insert two AA
batteries into battery cavities. Positive end of both batteries must
face down. Using a toothpick or similar sharp instrument, press
the R button to clear timer's memory.
Set time/day: Press and hold SET 2-5 seconds until hour begins to flash.
Press + or – to set current hour. To switch from AM to PM, press + or – twelve
times, until AM or PM appears in upper right corner of display screen. Press
SET again, minutes will flash. Press + or – to set current minute. Press PROG
to exit time setting mode.
PROGRAMMING THE TIMER
1.Press PROG to display ON 1 setting.
Display will look like this:
2. Set desired hour/minute to turn cycle ON:
Press SET, hour display will flash. Press
+ or – to set desired hour. Press SET again,
minute display will flash. Press + or – to set
desired minute.
3. Set desired hour/minute to turn cycle OFF:
Press SET again, ON 1 will flash. Press + to
display first cycle OFF time. Display will look
like this:
4. Repeat the procedure described in step 2
to program desired hour/minute to turn cycle
OFF. Press PROG to exit programming mode.
To program an additional cycle, press PROG,
then press + until ON 2 setting is displayed.
Display will look like this:
Repeat steps 2-4 to set desired ON/OFF time for cycle two.
Note: timer allows for two different ON/OFF cycles to be programmed.
IMPORTANT! Review programmed ON/OFF cycles: Press
!
PROG to display first cycle ON time. Press + to advance through
all programmed ON and OFF settings. Make sure there are no
overlapping ON or OFF times. Stop at any programmed setting
you want to change. To change any programmed cycle: Press
SET to enter timer programming mode, and repeat steps 2-4 to
reset ON and OFF times.To remove any unwanted programmed
cycles: Press RST-DST and setting will be deleted. Press
RST-DST again and deleted setting will be restored. Press PROG
to exit programming mode.
1
AM
PM
2
AUTO
ON
OFF
3
RCL-DST
R
4
+
PROG
SET
5
6
7
8
9
Consumer Support/ Service d'aide a la clientele / Servicio al consumidor (800) 561-4321
When finished programming desired ON/OFF cycles, connect the timer to the
wall switch (if you have not done so already). Make sure the timer in the OFF
mode (press the + button until OFF appears in the display) and turn the wall
switch to the off position. Screw the timer backing plate to wall switch plate.
Place the timer over backing plate by lining up screw holes below the batteries
and snapping the top of the timer onto the backing plate. Reinstall the two
short screws that you removed previously and close the battery door.
10
To use the timer: Press + until AUTO OFF or AUTO ON appears in display. In
AUTO ON mode, wall switch will be on at current time and will be turned off
at next programmed OFF time. In AUTO OFF mode, wall switch will be off at
11
current time and will be turned on at next programed ON time. Timer must be
in either AUTO ON or AUTO OFF mode for programmed settings to operate.
At the next programmed ON or OFF time, the timer's motor will move the wall
switch to the on or off position (you will hear the timer's motor as it moves the
switch).
To operate wall switch manually and override the timer:
Press + to display ON: Switch will remain in the ON position.
Press + to display OFF: Switch will remain in the OFF position.
Press + to display AUTO ON: turns switch on immediately until the next
programmed OFF time.
Press + to display AUTO OFF: turns switch off immediately until the next
programmed ON time.
DAYLIGHT SAVINGS FEATURE: Press RCL-DST to set time ahead one hour
(+1h will appear in lower right corner of display). Press RCL-DST again to exit
daylight savings mode and set time back one hour (+1h will disappear from
display).
NOTE: The low battery indicator light will illuminate when battery
!
power is low; batteries should be replaced within 7 days. If the
low battery indicator light is flashing, batteries must be
replaced within 5 minutes or programming will be lost and
you will have to reprogram the timer.
CONSUMER SUPPORT: (800) 561-4321
UNITED STATES AND CANADA
Users of this product are cautioned not to make modifications or changes
that are not approved by Southwire Co, doing so may void the compliance
of this product and may result in the loss of the user's authority to operate
the equipment.
FCC Digital Emissions Compliance
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two (2) conditions: (1) This device may not cause harmful
interference and (2) this device must accept any interference received
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced radio television technician for help.
CAUTION: To comply with the limits of the Class B digital device, pursuant
to Part 15 of the FCC Rules, this device is to comply with Class B limits.
All peripherals must be shielded and grounded. Operation with non-certified
peripherals or non-shielded cables may result in interference to radio
or reception.
MODIFICATION: Any changes or modifications not expressly approved
by the grantee of this device could void the user's authority to operate
the device.
Canadian Digital Apparatus Compliance
CAN ICES-003/NMB-003
www.woodshomeproducts.com

Advertisement

loading

Summary of Contents for Woods 59744

  • Page 1 Programming Manual for Model 59744 Battery Powered Switch-Mounted Timer When finished programming desired ON/OFF cycles, connect the timer to the wall switch (if you have not done so already). Make sure the timer in the OFF WARNING: TIMER IS INTENDED FOR INDOOR USE ONLY! mode (press the + button until OFF appears in the display) and turn the wall switch to the off position.
  • Page 2 Manuel de programmation pour le Programmateur à piles modèle 59744 – basculeur d’interrupteur Quand la programmation des cycles ON/OFF est terminée, montez le AVERTISSEMENT : POUR UTILISATION À L’INTÉRIEUR programmateur sur l’interrupteur mural si vous ne l’avez pas déjà fait.
  • Page 3 RCL -DST RCL -DST RC L-D Follow steps 3-5 below to RC L-D To use timer with toggle wall switch: RCL -DS RCL -DS PROG complete installation Pour utiliser la minuterie avec un PROG Suivez les étapes 3 à 5 interrupteur mural à...
  • Page 4 Manual de programación para el temporizador montado en el interruptor a pila modelo 59744 Cuando termine de programar los ciclos deseados de encendido/apagado, ADVERTENCIA: ¡EL TEMPORIZADOR ES SOLO PARA USO conecte el temporizador al interruptor de la pared si aún no lo ha hecho.