Preparation For Servicing - Toshiba MV19K2 Service Manual

Color television/video cassette recorder
Hide thumbs Also See for MV19K2:
Table of Contents

Advertisement

How to use the Servicing Fixture
1.
Unplug the connector CP351, CP355, CP502 and CP353, then remove the TV/VCR Block from the set.
2.
Unplug the connector CP810, CP820 and CP850, then remove the Main PCB from the VCR Block.
3.
Connect as shown in the below figure using the Service Fixture.
• Connect the Syscon PCB to the Main PCB with the cable JG162C and JG162D.
• Connect the Syscon PCB to the CRT PCB with the cable JG162Y.
4.
Remove the Jack/LED PCB from the set, then connect it with the Syscon PCB.
If necessary, connect CP351 (Front A/V Jack Input Terminal)
5.
Short circuit between TP1001 and Ground with the cable JG154.
(Refer to MAJOR COMPONENTS LOCATION GUIDE)
The EOT, BOT and Reel Sensor do not work at this moment.
6.
At that time, the STOP/EJECT button is available to insert and eject the Cassette Tape.
JG154
To Ground
All manuals and user guides at all-guides.com

PREPARATION FOR SERVICING

Front Cabinet
CRT PCB
CD850
Syscon PCB
CD601
TP1001
Jack/LED PCB
CP850
Main PCB
CP810
JG162Y
JG162D
JG162C
CD820
CD810
CP355
CD352
CD351
CP820
CP804

Advertisement