Servicing Fixtures And Tools; Preparation For Servicing - Toshiba MV13Q41 Service Manual

Color television/ video cassette recorder
Hide thumbs Also See for MV13Q41:
Table of Contents

Advertisement

Alignment Tape
ST-N5
ST-NF
VTR cleaning kit
JG022 Master Plane
JG180 AV Jack Jig
Ref. No.
Part No.
JG002B
APJG002B00
JG002E
APJG002E00
JG002F
APJG002F00
JG022
APJG022000
JG024A
APJG024A00
JG153
APJG153000
JG154
APJG154000
JG180
APJG180000
JG185
APJG185000
How to use the Servicing Fixture
1.
Remove the Syscon PCB from the set.
Be sure to place the parts on a paper so that they have no short-circuit each other.
2.
Short circuit between TP1001 and Ground with the cable JG154.
(The BOT, EOT, and the Reel Sensor do not work and the deck can be operated without a cassette tape.)
3.
In case of using a cassette tape, press the STOP/EJECT button to insert or eject a cassette tape.
Turn on the power and re-check the cable before checking the trouble points.

SERVICING FIXTURES AND TOOLS

Back tension cassette gauge
70909103
VTR lubrication kit
JG024A Reel Disk Height
Adjustment Jig
JG185 Tentelometer
Parts Name
Adapter
Dial Torque Gauge (10~90gf•cm)
Dial Torque Gauge (60~600gf•cm)
Master Plane
Reel Disk Height Adjustment Jig
X Value Adjustment Screwdriver
Cable
AV Jack Jig
Tentelometer

PREPARATION FOR SERVICING

Torque cassette gauge
(KT-300NR)
70909199
Grease
JG153 X Value Adjustment
Screwdriver
VSR Torque, Brake Torque (S Reel/T Reel Ass'y)
Brake Torque (T Reel Ass'y)
VSR Torque, Brake Torque (S Reel)
Reel Disk Height Adjustment
Reel Disk Height Adjustment
X Value Adjustment
Used to connect the test point of SERVICE and GROUND
PG Shifter Adjustment
Confirmation of Tape Tension on Playback
D1-1
Taper nut driver
70909228
JG002B
Adapter
JG002E
Dial Torque Gauge
(10~90gf•cm)
JG002F
(60~600gf•cm)
JG154 Cable
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents