Real Time Clock (RTC) Modification
S
Pre-Trip result & data
S
Trip Start
S
ISO Trip Header (Must be entered first via
S
Interrogation program)
Economy Mode Start
S
Economy Mode End
S
"Auto 2" Pre-Trip Start
S
"Auto 2" Pre-Trip End
S
Bulb Mode Start
S
Bulb Mode changes
S
Bulb Mode End
S
USDA Trip Comment
S
CTD Controlled Atmosphere Information
S
Humidification Start
S
Humidification End
S
USDA Probe Calibration
S
3.3.2
DataCORDER Configuration
NOTE
The DataCORDER software is integrated with
the Controller software.
Configuration to factory installed default configuration
is achieved via a common configuration card used for
controller functions, see section 3.1.2.
Changes to the factory default configuration must be
made with the Interrogation device.
Configuration:
Tells
the
operational
components are built into the container unit, how many
sensors to record, what recording interval should be
used, etc..
software
what
physical
ITEM
Sensor Logging
(Network)
Sensor Logging
(Thermistor)
Sensor Format
Sensor
Refer to section
Configuration
15, 30, 60 or
Logging Interval
Configuration
cards
Replacement Components Group.
The use of a programming card in the field should only
occur under unusual circumstances, such as a physical
component in the container unit is changed to a different
component, resulting in a new configuration for the
unit.
3-25
FACTORY
SETTING
DEFAULT
Average or
Average
Snapshot
Average,
Snapshot or
Average
USDA
1 or 2 byte
1 byte
2 sensors
3.3.5.f.
60 minutes
120 minutes
are
available
thru
T-268-07
CTD