All LP cylinders to be used with this appliance must be:
a. Constructed and marked in accordance with the U.S.
Department of Transportation (DOT) Specifications for LP-
Gas Cylinders, or the Standard for Cylinders, Spheres and
Tubes for Transportation of Dangerous Goods, CAN/CSA
B339, as applicable.
b. Provided with a listed overfilling prevention device.
c. Provided with a cylinder connection device compatible with
the connection for the appliance.
d. Only a 9 kg / 20 lb LP gas cylinder is to be used for this
appliance, approximately 46 cm / 18 in high & 30 cm / 12 in
diameter.
e. The use of an approved LP gas cylinder stabilizer, such as the
one included, must be used when using this appliance in order
to prevent the LP gas cylinder from tipping over.
CONNECTION:
1. Be sure the cylinder valve and appliance valves
are "off".
2. Place full LP gas cylinder on tank stabilizer ring.
3. Center the nipple in the cylinder valve and hold in place.
4. Using the other hand, turn the hand wheel clockwise until there
is a positive stop. Do not use tools.
5. Hand tighten only. When making the connection,
hold the regulator in a straight line with the cylinder valve, so
as not to cross thread the connection.
6. Leak test the connection. See section named "LEAK TEST".
LEAK TEST:
1. DO NOT USE OR PERMIT SOURCES OF IGNITION
IN THE AREA WHILE DOING THE LEAK TEST.
THIS INCLUDES SMOKING.
2. Leak testing should be done once per year or whenever the
LP gas cylinder or any other gas system part is taken apart,
serviced or replaced, whichever is more frequent.
3. Ensure all gas system coupling joints are tight and properly
attached.
4. Prepare a leak testing solution of half liquid detergent
and half water.
5. Apply the solution to the LP gas delivery system at points as
shown in illustration indicated on page 3.
6. If parts of the fitting begin to produce bubbles, spray liquid, or
if you smell liquid propane gas, immediately close the valve on
the tank.
7. Wait 5 minutes for any gas to dissipate.
8. After waiting for 5 minutes, the leak(s) must be stopped by
tightening the loose joints, if possible, or by replacing the
faulty parts(s) with the part(s) recommended by the appliance
manufacturer.
En-3
OUTLAND FIREBOWL
Owner & Safety Manual
OKANAGAN - OWNER & SAFETY MANUAL
®
WARNING:
Ensure that the appliance is kept at a minimum distance of
0.91 m / 36 in from the gas cylinder.
Appliance
LEAK TEST: Apply the solution to the LP gas
delivery system at points:
1. Firebowl Valve Coupling
2. Gas Hose Regulator
3. Cylinder Valve Coupling
2. Gas Hose
Regulator
Heat Sensitive
Hand Wheel
LEAK TEST: Apply the solution to the LP gas delivery system at points.
Valve coupling regulator & Cylinder Coupling.
Tank Ring
Minimum
0.91 m / 36 in
!
Caution:
LP Cylinder
Trip Hazard!
3. Cylinder Valve
Coupling
Check Valve
Nipple with Flow
Limiting Device
D.875.000.V0
Tank Ring
Cylinder
Shut Off
Valve

Advertisement

loading