FR95 SWEPAC FR 95 is used to pack ballast under foundations, on pavements, in trenches, etc. The rounded base plate makes the machine very suitable for packing around pillars, foundations, wells, etc. In places with poor access, for example in pipe and cable trenches, the machine is easy to use.
SAFETY INSTRUCTIONS STANDARDS Noise • Before using the machine, the operator must be Measurement according to the standard EN 500-4 informed of the manufacturer’s safety instructions Rev.1: 1998, Annex C: Measurement uncertainty ± and instructions for use. 0,5dB (A) i 95% of measurements. •...
FR95 SIGNS Warning Signs Machine plate Before use, carefully read through the manual and safety regulations in order to be able to handle the machine in a proper manner. Make sure that the handbook is always available 1. Manufacturer. 2. Country of manufacture.
Engine oil ..SAE10W-30 Engine oil change: first oil change after 20 hours then every 100 hours of operation. Note! Vibration element for the FR95 is grease lubricated. The bearing can not be re-greased, and is permanently lubricated. This means that no oil is needed for the vibration...
DAILY SUPERVISION Oil/Fuel Leakage Fuel Check Check every day that the engine is not leaking oil or Check that there is fuel in the tank. Top up if fuel. If a leak is discovered, the machine may not be necessary. operated until the fault has been remedied.
FR95 Oil level Engine power switch Idle Full throttle Open Closed Throttle lever- Fuel cock Choke BEFORE STARTING AFTER STARTING See Daily Supervision, page 8. Switch the throttle lever to idle. Open the choke gradually. STARTING Run the engine for around 5 minutes.
FR95 DRIVING INSTRUCTIONS The vibrating element starts when the throttle is increased. The best packing is achieved at full engine RPM. Avoid running the engine at other RPM. The vibrating element of the machine will stop when the throttle switch is set to idling.
2. Type: FR95 3. Motor power: 3.6 kW The product complies with the following directives: 2006/42/EC 2000 / 14 /EC 2004/108/EC EN 500-1 EN 500-4 Technical documentation available from: Swepac AB, Bergvägen 7 34132 Ljungby SE Tomas Johansson / Product Engineer...