General Information; California Proposition; Pump Operation - Pentair Hydromatic H-03-000 Installation And Service Manual

Standard electrical control panel
Table of Contents

Advertisement

General
Information
Thank you for purchasing your
Hydromatic
control panel. To
®
help ensure years of trouble-
free op er a tion, please read the
fol low ing manual carefully.
Before Operation:
Read
the
following
tions care ful ly. Reasonable care
and safe meth ods should be
practiced. Check local codes and
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product.
Read this manual
completely before using this
product and refer to it often for
con tin ued safe product use. DO
NOT THROW AWAY OR
LOSE THIS MAN U AL. Keep it
in a safe place so that you may refer
to it often.
Unpacking Panel:
Remove
panel
from
When un pack ing unit, check for
con cealed damage. Claims for
damage must be made at the
receiving end through the delivery
carrier.
Dam age
processed from the factory.

CALIFORNIA PROPOSITION

65 WARNING:
This product and
related
accessories
chemicals known to the State of
California to cause cancer, birth
defects or other reproductive
harm.
2
WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
Electrical Connections:
The contractor must conform
to the latest requirements of the
National Electrical Code. All
in struc-
conduit and ca bles shall be in
accordance with NEC Code
NFPA #70. To maintain UL and
CSA ENCL rating, use the same
type UL and CSA weatherproof
con duit hubs when connecting to
this en clo sure. Prior to conducting
any in stal la tion, repair or service
with re gard to the control panel,
refer to the schematic appropriate
for that panel. The schematic will
provide guidance with regard to
the terminal block con nec tions.
CAUTION:
enclosures do not provide
grounding conduit con nec tions.
Use grounding bush ing and
jumper wires.
carton.
Make the Following Electrical
Con nec tions:
a. Connect the pump leads to
the control panel. If pump
is single phase and the panel
cannot
be
has start ca pac i tor, start
relay and run ca pac i tor, it is
critical that the pump leads
be connected prop er ly. The
White, Black, and Red pump
leads must be connected to
the
contain
as direct ed by the panel
schematic and the label on
the back panel below the
terminals.
b. Connect the pump heat sensor
and seal failure leads (if
available on the pump) to the
Nonmetallic
ap pro pri ate
terminals
appropriate ter mi nal blocks in
the control panel. If the heat
sensor lead from the pump
is wired as indicated, re move
jumpers as defined by the
sche mat ic.
c. Connect all the float control
leads to the appropriate panel
terminals. Contractor must be
very careful in locating the
floats at the proper elevations.
The maximum dis tance from
the control panel to the floats
is the lesser of l00 feet,
or the maximum distance
rec om mend ed for the pump.
d. Before connecting power to the
control panel, make sure all
con trol switches (e.g. H-O-A
switch) and protective devices
(e.g. breakers) are in the Off
po si tion. Now connect power
to the terminal block or the
circuit break er as directed by
the sche mat ic.
e. Control panel must be grounded
properly per NEC and/or local
codes. To facilitate this, a
ground lug is provided on the
control panel.
Pump
Operation
1. Check
junction
moisture. Moisture may cause
chattering of relays/contactors.
2. If pump is single phase with
start capacitor, start relay
and run capacitor in panel.
Check that pump White,
Black, and Red
wires are con nect ed to pan el
correct ly.
3. WARNING! Live voltage can
kill! Check incoming power
volt age to make sure that
it is correct for panel and
pump model.
box
for