General Information; Panel Installation; Panel Operations - Pentair Hydromatic SPC-PANEL Installation And Service Manual

Pump controls for 2 hp grinder pumps, simplex, single phase pump control panel
Table of Contents

Advertisement

General
Information
Thank you for purchasing your
Hydromatic
control panel. To
®
help ensure years of trouble-
free op er a tion, please read the
fol low ing manual carefully.
Before Operation:
Read
the
following
tions care ful ly. Reasonable care
and safe meth ods should be
practiced. Check local codes and
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product.
Read this manual
completely before using this
product and refer to it often
for con tin ued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MAN U AL.
it in a safe place so that you may
refer to it when needed.
Unpacking Panel:
Remove
panel
from
When un pack ing unit, check for
con cealed damage. Claims for
damage must be made at the
receiving end through the delivery
carrier.
Dam age
processed from the factory.
WARNING: Before handling
these Hydromatic pumps and
controls, always disconnect the
power first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
2
CALIFORNIA PROPOSITION
65 WARNING:
related
chemicals known to the State of
California to cause cancer, birth
defects or other reproductive
harm.
Panel
Installation
in struc-
Electrical Connections:
The contractor must conform
to the latest requirements of the
National Electrical Code. All
conduit and ca bles shall be in
accordance with NEC code NFPA
#70. To maintain UL type 4X
and CSA ENCL 4 rating, use UL
type 4 and CSA weatherproof
con duit hubs when connecting to
this enclosure. Prior to conducting
any in stal la tion, repair or service
with re gard to the control panel,
refer to the schematic ap pro pri ate
Keep
for that panel. The sche mat ic will
provide guidance with regard to
the terminal block con nec tions.
CAUTION:
carton.
enclosures do not provide
grounding conduit con nec tions.
Use grounding bush ing and
jumper wires.
cannot
be
Make the Following Electrical
Con nec tions:
a. Connect the pump leads to
the
connecting the pump leads
it is very critical that the
prop er sequence be main tained.
On single phase pumps, the
color coded pump leads black,
white, red, must be connected
to the appropriate terminals
as directed by the control
schematic.
This product and
accessories
contain
Nonmetallic
control
panel.
When
b. Connect the pump heat sensor
and seal failure leads (if
available on the pump) to the
appropriate ter mi nal blocks
in the control panel. If the
heat sensor lead from the
pump is wired as indicated,
re move jumpers as defined by
the sche mat ic.
c. Connect all the float control
leads to the appropriate panel
terminal
blocks.
tor must be very careful in
locating the floats at the proper
elevations.
The
distance from the control panel
and the floats is the lesser
of l00 feet, or the maximum
distance recommended for
the pump.
d. Before connecting power to
the control panel, make sure
all the control switches (e.g.
H-O-A switch) and protective
devices (e.g. breakers) are in
the Off position. Now connect
power to the circuit breaker as
directed by the schematic.
e. Power must be the correct
voltage for the pump model.
Power must have neutral
to supply 120 volts to the
control circuit.
f. Control panel must be grounded
properly per NEC and/or local
codes. To facilitate this, a
ground lug is provided on the
control panel.
Panel
Operations
WARNING: Before handling
these Hydromatic pumps and
controls, always disconnect the
power first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.