FG Wilson OLYMPIAN 1001 Series Manual page 22

Generating set
Table of Contents

Advertisement

Flash
Condition description
code
466
Number 6 injector unit failed the
contribution test
513
Bank 1 open circuit: low
514
Bank 2 open circuit: low
515
Bank 1 short circuit to earth or B+: low
521
Bank 2 short circuit to earth or B+: low
524
Short circuit between bank 1 and bank 2
525
Injector unit driver circuit fault ECM unable
to supply sufficient voltage to injector units
612
Incorrect ECM installed for the camshaft
timing plate
614
Engine family rating code and ECM do not
match
621
Engine using default rating
622
Engine using field default rating
623
Invalid engine rating code
624
Field default active
625
ECM fault
626
Unexpected ECM reset fault
631
ROM self test fault
632
RAM self test fault
655
Programmable parameter list level
incompatible
661
RAM programmable parameter list corrupt
664
Calibration level incompatible
665
Programmable parameter memory content
corrupt
* These codes, if flashed, will not affect the operation of the engine in a generating set application:
Note:
The engine protection systems e.g. low oil pressure, high coolant temperature, are within the control of the generating set control
panel. These sensors will shut the engine down before the ECM sensors.
Comments
Found by the ECM
Injector units for cylinders 1,2 and 3
have an open circuit in the high voltage
supply
Injector units for cylinders 4, 5 and 6
have an open circuit in the high voltage
supply
Injector units for cylinders 1,2 and 3
have short circuit to earth or B+
Injector units for cylinders 4, 5 and 6
have short circuit to earth or B+
Short circuit between bank 1 and bank
2
Engine wiring loom fault.
No match between the ECM and the
camshaft position sensor
ECM programming fault
Engine operates AL25 HP, default
Engine limited to 160 HP Options not
available
-
Programming problem
ECM software fault
Temporary ECM power failure
ECM failure
ECM failure
Programming problem. ECM memory
problem
Programming problem ECM memory
problem
Programming problem
ECM failure
18
Probable causes
-
Open circuit
Open circuit
Short circuit in wiring loom
Short circuit in wiring loom
Short circuit in wiring loom
Injector unit wiring loom fault. ECM fault
Incorrect ECM fitted
Components not compatible
ECM installed but not programmed
ECM installed but not programmed
ECM not programmed correctly
ECM fault
Replace ECM
Battery connection fault
Internal ECM fault
Internal ECM fault
Programming fault
Programming fault
Programming problem
Internal ECM fault