FAULT
SYMPTOM
Alam for Low Battery
"LOW BATERY
Voltage
VOLTAGE" Alarm in event
Log, Amber battery LED
Illuminates
Alarm for Not in
"NOT IN AUTO MODE"
Automatic Mode
Alarm in event Log, Amber
(Standby Sets Only)
LED Illuminates
Alarm for
'APPROACHING HIGH
Approaching High
COOLANT TEMP' Alarm
Engine Temp
in event Log, Amber LED
Illuminates
Alarm for
"APPROACHING LOW
approaching low oil
OIL PRESSURE" Alarm in
pressure
event Log, Amber LED
Illuminates
Alarm for Battery
'BATTERY CHARGER
Charger Failure
FAILURE' Alarm in event
Log, Amber LED
Illuminates
REMEDY
1. Refer to a qualified generating set technician.
1. Check module is in 'Auto' mode
2. Check Emergency Stop Pushbuttons are not pressed.
3. Check Circuit Breaker is on (handle up).
4. Refer to a qualified generating set technician.
1. Refer to a qualified generating set technician.
1. Refer to a qualified generating set technician.
1. Refer to a qualified generating set technician.