Download Print this page

Sony HDC-700A Operation Manual page 26

Hd color video camera

Advertisement

Location and Function of Parts
1 Up tally lamp
Lights when the camera receives a red tally signal.
When the CALL button on the MSU-700 Master Setup
Unit or the RCP-700 series Remote Control Panel is
pressed, the lamp lights if previously off or goes off if
previously on. The brightness of the lamp may be
adjusted using the menu. Setting the UP TALLY
switch on the rear panel to OFF will keep the lamp
from lighting.
Attach a supplied number plate (0 through 9) to
display the camera number.
For more information on adjusting the lamp brightness or
attaching a number plate, contact a Sony service or sales
representative.
2 Safety lock
Locks the side panel to prevent accidental opening. To
open the side panel, loosen the side panel lock screws,
slide the safety lock towards the lens, and open the
panel.
The side panel locks automatically when closed.
For more information, contact a Sony service or sales
representative.
3 Camera number plate
Attach a light gray number plate (supplied) to display
the camera number.
For more information on attaching a number plate, contact
a Sony service or sales representative.
4 Side panel lock screws
These screws secure the side panel. Turn clockwise
until tight to lock the panel.
5 Lens lock and knob
These lock the lens. To attach or remove a lens, turn
the knob counterclockwise until the lens lock is
horizontal. To secure the lens, turn the knob clockwise
until the lens lock is vertical.
6 Cable clamp
Used to secure the fiber optic cable. The clamp is
designed for the FC2-PD50 and FC2-PD250.
For more information on using the cable clamp, contact a
Sony service or sales representative.
6(E)
7 Accessory bracket
Used to secure optional accessories such as the BKP-
7911/7912 Script Holder or Focus/Zoom Demand.
For more information on attaching an accessory, see the
accessory's Operation Manual.
8 MIC IN CH-1 and CH-2 connectors (XLR 3-pin)
Used to input microphone or line signals. Line signals
(–20 dB) may be selected using the menu.
9 PROMPTER connector (BNC type)
Used to output the signal input from the HDCU-700A
Camera Control Unit's PROMPTER INPUT
connector.
!º TEST OUT (test signal output) connector
(BNC type)
Used to output the signal selected by the video signal
select buttons on the rear panel (see page 9(E)). If the
RET 1 or RET 2 button is pushed in, the output will be
a return video signal.
!¡ TRACKER connector (10-pin)
Used for communication between the camera operator
and the tracker, and also for intercom channels 1 and 2.
It also supplies the up tally signal and the program
audio signal.
!™ RET (return video) CONTROL connector
(6-pin)
Allows an external controller to switch return video 1,
2, and 3, as well as turn the intercom microphone on
and off.
!£ SCRIPT (script light) connector (4-pin)
Supplies power (12 V, 5 W maximum) to a script light.
!¢ REMOTE connector (8-pin)
Used to connect the camera to an optional MSU-700
Master Setup Unit or RCP-700 series Remote Control
Panel, via a CCA cable. The connected unit may then
control the HDC-700A.
!∞ CCU (camera control unit) connector (optical /
electrical multi-connector)
Connects the HDC-700A to an HDCU-700A Camera
Control Unit using an optical / electrical cable. Power
and video, audio, and control signals are passed
between the camera and the control unit using just one
cable.

Advertisement

loading

This manual is also suitable for:

Hdc-700a/l