3. Absolute Maximum Ratings

Parameter
Storage Temperature
Storage Humidity (@ 40℃)
Caution
: The specifications above the Table define levels at which permanent damage
to the device can occur. Function operation is not guaranteed under these conditions.
Operating at absolute maximum conditions for extend periods can adversely affect the
long-term reliability of the device.
• Other conditions
1) Do not use or store modules in the corrosive atmosphere, especially where chloride
gas, sulfide gas, acid, alkali, salt or the like are contained
Also, avoid exposure to moisture
2) Store the modules where the temperature
and relative humidity do not exceed 5 to 40℃ and 20 to 60%
3) Assemble the modules within 6 months
Check the soldering ability in case of 6 months over

4. Operating Test Conditions

Parameter
Operating Temperature
Operating Humidity (40℃)
Supply Voltage
1) Test condition : AP connection Ping test mode(not continuous Tx and T-Put mode)
LG Innotek Confidential : This document is protected by security policies and laws.
USER MANUAL
MODEL NAME : LCWB-002
Min
-40
-
Min
0
-
4.5
10.8
REV. NO : v1.0
PAGE :
4 / 10
Max
Unit
+100
90
%
Typ
Max
-
+85
-
85
5.0
5.5
12
13.2
[Restricted]