TECHNICAL DATA

Gas Type
Gas Connection
Number of Injectors
Control Max Operating Temperature
Inlet Pressure Cold
Heat Input (Gross)

REPLACEMENT PARTS

1. Loose coals - The ceramic coals supplied with this appliance can be replaced at service intervals depending
on their condition. If the coals do require replacement, the consumer can do so provided that the Ceramic
Component Layout Instructions (pages 16 - 21) are adhered to. Under no circumstances should additional/extra
coals be added. Only genuine Legend replacement parts should be used.
Order Ref: VANcoa
2. Front Coal, and Fuel Bed, Side Cheeks and Rear Coal - All these ceramic components can be replaced at
service intervals depending on their condition. If the coals do require replacement, the consumer can do so
provided that the Ceramic Component Layout Instructions (pages 16 - 21) are adhered to. Only genuine Legend
replacement parts should be used.
Order Ref: SPI2FC, VanFB, VanSC, VanCB
3. Oxygen Depletion Sensing Pilot - In the unlikely event of a pilot failure, the pilot assembly should only be
replaced by a CORGI Registered Engineer. The user must not carry out this work.
Order Ref: SSPI2PIL
4. Control Tap - In the unlikely event of control tap failure, the assembly should only be replaced by a CORGI
Registered Engineer. The user must not carry out this work.
Order Ref: SPI2CON
5. Main Injector - In the unlikely event of main injector failure, the fitting should only be replaced by a CORGI
Registered Engineer. The user must not carry out this work.
Order Ref: SPI2INJ
Natural Gas Only
8mm
One
o
80
c
20 mbar (8" W.G.)
6.9 kW
11