Troubleshooting
PROBLEM
Lid will not open or is
very slow to open
Pump starts while lid is
still open
LP error is showing
CLO error is showing
POSSIBLE SOLUTION
Ensure all cycles are complete
Adjust cycle times if necessary
Check solenoid valve
Check control solenoid valve
Check piston
Check silicone tubing
Check circuit board
Check microswitch
Check circuit board
Check fuse
Check power cord
Check transformer
Check silicone tubing for leaks
Check control solenoid valve
Check solenoid valve
Check circuit board
PAGE
19
21
14
18
17
18
10
18
19
20
18
9