Small Control Solenoid Valve; Large Control Solenoid Valve - VacPak-It 186VMC16F Service Manual

Floor model chamber vacuum sealer
Hide thumbs Also See for 186VMC16F:
Table of Contents

Advertisement

Part Replacement Continued

Small Control Solenoid Valve

Time Estimate: Approximately 20 minutes
Testing: Good = Continuity between wires
Bad = No continuity between wires
Part: #186P16FSV (186VMC16F Only)
1. Follow pre-maintenance steps on page 10
2. Remove Phillips head screws from the rear panel
of the machine
Note: 11 screws on 186VMC16F
3. Remove wires connected to the main circuit
board, note locations
4. Remove Phillips head screw from plastic hose
clamp (Fig. 36)
5. Remove hoses by pulling off of barb fittings on
valve (Fig. 37)
6. Installation is reverse of removal steps

Large Control Solenoid Valve

Time Estimate: Approximately 20 minutes
Testing: Good = Continuity between wires
~43.0 Ohms of resistance
Bad = No continuity between wires
Part: #186P20F54
1. Follow pre-maintenance steps on page 10
2. Remove Phillips head screws from the rear
panels of the machine
Note: 15 screws on 186VMC20F and
186VMC20FGF
Continued on Page 21
20
Fig. 36
Fig. 37
Fig. 38