1. Use
The electric hoist is designated for lifting the fixed loads only. It shall not be
used in the industrial service and professionally in the construction or
business.
2. Parts and Controls
3. Technical specification
type
Model
Capacity
Max. lift height
Speed of lifting
Rope diameter
Strength of rope in stroke
Operation / turn on time
Power
Voltage
Cover
Class protection
Sound power LwA
Weight
* Operating mode S3-20% / 10 = Intermittent operation without start-up. This means that within 10
minutes the maximum operating time is 20% (2min)
XT108250
YT‐125/250‐A
without pulley
125
12
8m/min
3mm
2
1870N/mm
S3‐20% / 10min
230V – 50Hz
500W
IP54
I
71dB(A)
12kg
1. Carrier stirrups
2. Pulley attachment
3. End-switch (up)
4. End-switch (down)
5. Steel rope
6. End-switch stop (up)
7. Pulley hook
8. Power cord
9. Controller
10. Direction controller
11. Emergency STOP Switch
12. Controller cord
13. Engine
with pulley
without pulley
250
6
4m/min
XT108600
YT‐300/600‐G
with pulley
300
12
8m/min
4m/min
4,5mm
2
1870N/mm
S3‐20% / 10min
230V – 50Hz
1000W
IP54
I
71dB(A)
18kg
600
6