Installation; Compressor Handling; Transport And Storage; Positioning And Securing - Emerson Copeland YF05K1E Application Manuallines

Scroll compressors for refrigeration applications
Table of Contents

Advertisement

3

Installation

WARNING
High pressure! Injury to skin and eyes possible! Be careful when opening
connections on a pressurized item.
3.1

Compressor handling

3.1.1 Transport and storage

WARNING
Risk of collapse! Personal injuries! Move compressors only with
appropriate mechanical or handling equipment according to weight. Keep in
the upright position. Respect stacking loads according to Figure 4. Check the
tilting stability and if needed take action to ensure the stability of the stacked
loads. Keep the packaging dry at all times.
Respect the maximum number of identical packages which may be stacked on one
another, where "n" is the limiting number:
Transport: n = 1
Storage: n = 2
Figure 4: Maximum stacking loads for transport and storage
The compressor tilt angle should not exceed 30° during transport and handling. This will prevent oil
f rom exiting through the suction stub. A tilt angle of maximum 45° is allowed f or a very short time.
Tilting the compressor more than 45° might affect its lubrication at start-up.
NOTE: The compressor is pre-charged with dry air to avoid any moisture contamination.

3.1.2 Positioning and securing

IMPORTANT
Handling damage! Compressor malfunction! Only use the lif ting eyes
whenever the compressor requires positioning. Using discharge or suction
connections for lifting may cause damage or leaks.
The compressor should be kept vertical during handling.
The discharge connection plug should be removed first before pulling the suction connection plug to
allow the dry air pressure inside the compressor to escape. Pulling the plugs in this sequence
prevents oil mist from coating the suction tube making brazing difficult. The copper-coated steel
suction tube should be cleaned before brazing.
The plugs must be removed as late as possible before brazing so that the air humidity does not affect
the oil characteristics.
For
YF*K1E
compressors,
the suction connection plug must be left in place until the compressor is set into the unit.
No object, eg, a swaging tool should be inserted deeper than 51 mm into the suction tube as it might
damage the suction screen and motor.

3.1.3 Installation location

Ensure the compressors are installed on a solid level base. For single-compressor applications, the
compressor tilt angle during operation should not exceed 15° to allow adequate lubrication. For
multiple-compressor parallel conf igurations, the compressors must be positioned completely
vertically on a totally horizontal surface or rail.
AGL_Ref_ST_YFK1E_EN_Rev01
as oil might spill out of the suction connection located low on the shell,
7

Advertisement

Table of Contents
loading

Table of Contents