Page 1
OPERATION MANUAL PERMANENT PL ATE LIFTING MAGNET Type GP250 OPERATING AND MAINTENANCE INSTRUCTIONS FOR MODEL GP250 Hulínská 1799/1; 767 01 KROMĚŘÍŽ; Czech Republic FAX: +420 573 351 035; TEL.: +420 573 341 641 www.walmag.cz; info@walmag.cz...
Page 3
• Failure to comply with the operating and Type GP250 maintenance instructions; • use considered as being other than OPERATING MAINTENANCE normal; INSTRUCTIONS FOR MODEL GP250 • normal wear; • modifications or repairs not performed by FOREWORD WALMAG MAGNETICS or an authorised have purchased WALMAG agent.
Page 4
WORKLOAD LIMIT (WLL) or action that could have physical injury or damage to the equipment as a result. The workload limit of type GP250 Safety instructions Horizontal = 250 kg 01. Never use this magnet before these Vertical = 80 kg instructions have been read and understood.
Page 5
Never exceed the maximum weight and/or dimensions Never place the magnet for the material thickness over a large hole or bore stated in the table on page 5. UNSAFE APPLICATIONS NEVER LIFT MORE THAN ONE WORK PIECE AT A TIME (THIN PLATES) NEVER LIFT A LOAD WITH A CONTACT SURFACE SMALLER THAN THE FOOTPRINT OF THE MAGNET.
Page 6
4. Lower the load and stabilize it before WARNING Never put your hand between removing/breaking off the magnet the magnet and the workpiece! 5. Unlock the release handle and pull the same to break off the magnet. Now lift the 3.