• Put the device in standby mode and unplug the device from the mains prior to replacing the battery.
• Follow the battery manufacturer's instructions when installing new batteries.
• Please find more information in the User Guide document to activate the battery.
Specific instructions regarding appliances with R290 gas
• The appliance AU5610F0 contains approximately 0,246 kg of refrigerant gas.
• The applicance AU5620F0 contains approximately 0,285 kg of refrigerant gas.
• The maximum refrigerant charge amount is 0.3 kg; R290 refrigerant gas complies with European
environmental directives.
• The mimum rated airflow is 300 m
3
/h;
• A surface area greater than 12m² for AU5610F0 and 14m² for AU5620F0 (with ceiling height > 2m) is
necessary for the installation, use and storage of the appliance
• Stagnation of possible leaks of refrigerant gas in unventilated rooms could lead to fire or an
explosion hazard should the refrigerant come in contact with electric heaters, stoves or other
sources of ignition.
• Use care when storing the appliance to prevent mechanical faults.
• Only persons authorized by an accredited agency certifying their competence to handle refrigerants
in compliance with sector legislation should work on refrigerant circuits.
• Maintenance and repairs requiring the assistance of other qualified personnel must be carried out
under the supervision of specialists in the use of inflammable refrigerants.
• Do not use means to accelerate the defrosting process or to clean, other than those recommended
by the manufacturer.
• The appliance shall be stored in a room without continuously operating ignition sources (for
example: open flames, an operating gas appliance or an operating electric heater)
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.

PRECAUTIONS OF USE

This appliance is designed for household use only. It should not be used for industrial applications.
The appliance must be installed in accordance with the regulations in force in your country. The
working temperature is between 16°C and 35°C.
Do not pull on the power cord or the appliance, even when unplugging it from a wall socket.
Always unroll the power cord completely before use.
Do not use the appliance in a dusty room or a location where there is a risk of fire.
Never put objects inside the appliance (e.g. needles, etc.).
Do not use an extension lead.
Never use the appliance in an inclined or horizontal position. Place the appliance on a flat stable
surface.
Do not place heavy items or children on top of the appliance.
Do not cover the appliance.
Do not cover the air inlet and/or outlet grills.
Do not touch the appliance with wet hands.
Stop your appliance by using the (A) button before unplugging it.
Do not use the appliance outdoors.
The warranty will be invalidated if damage occurs due to incorrect use.
- TRANSPORTATION
• Caution: your device includes a refrigerating compressor; laying the device flat could lead to malfunctions.
• After transportation, do not turn on the appliance for at least one hour before starting it.
- STORAGE
• If you do not use the device, it must be placed in a well-ventilated area where the room corresponds
to the room area as specified for operation and away from humidity.
• Before storage, be sure to pull out the water outlet drain underside (#9), and allow the water to
drain out in a basin. (fig. 1) Run the unit in fan mode only for a few hours to dry any moisture on the
internal cold exchangers to prevent mold.
14
Fig.1
- CLEANING & MAINTENANCE
Before cleaning or maintenance, turn the appliance off and always unplug the appliance.
Cleaning: Wipe with a soft dry cloth. Never wash the air conditioner with water. Never use volatile
substance such as gasoline or polishing powder to clean the appliance.
Air filter maintenance: It is necessary to clean the air filter after using it for about 100 hours. Stop the
appliance and then pull back the air filter. (fig.2) Use a vaccum cleaner, water or a soft dry cloth to
clean the filter, and then reinstall it. Do not use the appliance without the filter.
Fig.2
OPERATING INSTRUCTIONS
The electrical facilities of the room, as well as the installation and use of the appliance must comply
with the standards in force in your country.
Before first use, ensure that the voltage, frequency and power of your appliance are suitable for your
electrical supply.
Your device must operate with an earthed power socket. It is a class I appliance.
Before switching on your appliance, ensure that:
• The appliance is positioned in accordance with the instructions in this manual;
• The air intake and outlet grills are completely unobstructed;
• The appliance is placed on a stable horizontal surface;
• Do not place under a clothesline or any other object likely to cause water to fall in the product.
N.B.: You are advised to unplug the appliance when not in use.