Before the installation, make sure that the module packages contain all the elements. Current version of the operation manual can be accessed at http://enelion.com/en/help/. See the contents of the manual before initiating any activities related to the installation or the activation of the charger.
Wallbox Adspace - Assembly manual 8 - 2021 1. Important information 1.1. General Provisions It is forbidden to use any extensions of the charging ca- ble. Installation and servicing of the device must be per- The manufacturer is not responsible for loss of health formed by qualified and authorized persons, and re-...
The 3 mm Allen key – included with the charger accessories as Enelion Bridge, Enelion MID or Enelion – is needed to open (or close) the Enelion Wall- RCM B protection. Some parameters and functions can box Adspace. No other tool is necessary for this be changed by reprogramming the device with the use operation.
Page 7
Wallbox Adspace - Assembly manual 8 - 2021 6. Holding the front panel in the same plane, slide it downwards from the top groove of the device. Fig. 3: Inserting an Allen key. 3. Turn the key counterclockwise until the locking pin is aligned with the side of the charger.
2. installation of a type A residual current device (RCD A 30 mA/40 A) in the switchboard with the 3.2. Recommended communication net- application of Enelion RCM B – type B Residual work Current Monitor, attached to the charging termi- nal.
Wallbox Adspace - Assembly manual 8 - 2021 Enelion devices equipped with the Enelion Bridge mod- 3. 100 cm clearance below the bottom edge of the ule can use the Internet connection via the Ethernet in- device. terface in the LAN network. In order to utilize this func-...
The opening diameter for the communi- Fig. 11: Mounting holes of Enelion Wallbox Adspace as cation cable gland is 19 mm. seen from the back of the device.
(both in the version with a gland in the upper and lower part of the device) Fig. 12: Locations of cable entry points in Enelion Wall- and the optimal cable lengths. Mounting holes box Adspace.
Power connection ply cables may be connected to the terminals or directly to the approved integrated MID meter. Enelion Wallbox Adspace comes in various types. De- pending on which type is being installed, the power sup- Variant 1 Variant 2...
INFO For both charging sockets to function in Ene- 3. Insert the power supply cables into the terminals. lion Wallbox Adspace the voltage must be sup- plied to the electrical connection clamps of both charge controllers. The steps described below should be applied to the terminals of both charg- ing sockets.
5.1.3. RCM B Connection wires of the cable with sleeve terminals. Enelion RCM B – Residual Current Monitor type B ac- 3. Insert the power cables into the terminals of the cessory. Enelion RCM B in combination with the RCD MID meter and tighten them.
If the communication between the devices is expected bles (All three phases and neutral cord.) to be via Enelion Chain network, the cables should be connected to the charge controller. Two cores of the communication cable and the screen grounding are used for communication.
Page 16
Fig. 26: Termination diagram. Fig. 27: A sample jumper. Fig. 24: Diagram of Enelion Chain communica- tion cables connection (variant A) Fig. 25: Diagram of Enelion Chain communica- Fig. 28: The place of applying the terminating...
It activates with the ap- pearance of voltage in the charging controller terminals. To provide the Internet connection to a charger equipped with Enelion Bridge module via Ethernet in- terface: 1. Insert the Ethernet cable into the device through the gland for communication cables.
Wallbox Adspace - Assembly manual 8 - 2021 6. Maintenance The device is designed to operate in temperatures from −25 °C to 55 °C. The manufacturer does not guarantee the proper functioning of the charging station in temper- atures outside the specified range. Chargers that are damaged because of exposure to temperatures below −25 °C or above 55 °C are not covered under the war-...
Wallbox Adspace - Assembly manual 8 - 2021 7. Technical data 7.1. Enelion Wallbox Adspace Electrical data Routing of the power cord Surface mounted Recommended minimum cross-section Power cord cross-section • 2 cords 5 x 6,0 mm (32 A nominal current)
Page 20
Wallbox Adspace - Assembly manual 8 - 2021 Ambient conditions Working temperature from −25 °C do 55 °C Storage temperature range from −40 °C do 80 °C Permitted relative air humidity from 5% do 95% Elevation above the sea level...