3. Remove control access panel.
4. Push in gas control knob (refer to Fig. 3 or 4) slightly
and turn clockwise
to OFF.
NOTE: Knob cannot be turned from PILOT to OFF unless
knob is pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow item 1 in the Warning above. If
you don't smell gas, go to next step.
6. Remove the pilot access panel located below and
behind the gas control unit.
7. Find the pilot—follow metal tube from gas control.
The pilot is between the two burner tubes behind the pilot
access panel.
8. Turn knob on gas control counterclockwise
PILOT.
9. Push in control knob all the way and hold in. Immedi-
ately light the pilot with a match. Continue to hold the
control knob in for about one (1) minute after the pilot is lit.
Release knob and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5-10.
10.Replace pilot access panel.
11.Turn gas control knob counterclockwise
ON.
12.Replace control access panel.
13.Turn on all electric power to the appliance.
14.Set thermostat to desired setting.
To Turn Off Appliance
VACATION SHUTDOWN—Turn gas control knob
clockwise
from ON to PILOT. Pilot will remain lit,
to
ready for return to normal service without relighting.
COMPLETE SHUTDOWN—Push in gas control knob
slightly and turn clockwise
Both pilot and main burner are shut off. Follow lighting
procedure above to resume normal operation.
7
to
to OFF. Do not force.