Before each intervention to the machine or its packaging, all operators using the machine must read and follow the instructions in the manual very carefully! Hydroscand Machine AB declines any responsibility for damage to persons, things or to the machine itself, arising from its incorrect use, negligence and/or superficial interpretations of safety concepts in this manual.
The skiving machine is designed, manufactured and protected for skiving hydraulic hoses with dimensions from 3/16” up to 2”. Any other use is excluded by Hydroscand Machine AB, who shall be exempted from any liability for damage to people, property or the machine itself, caused by the improper use of the machine.
When unpacking the machine make sure that the machine is in perfect condition and that the package is containing the parts described. Hydroscand Machine AB does not respond to any errors or missing parts that are NOT reported within eight (8) days from delivery.
General precautions. Any tampering or any maneuvering of the machine NOT described in this manual may cause damage to people, property or the machine itself and will exempt Hydroscand Machine AB from any damages. Hydroscand Machine AB Kungsvägen 22 Phone: +46(0) 225-57330 S-783 35 SÄTER...
During this stage, make sure that the Start/Stop button and the Emergency switch are not blocked and that there is sufficient visibility and lighting on the machine, the surrounding area and base. Hydroscand Machine AB Kungsvägen 22 Phone: +46(0) 225-57330 S-783 35 SÄTER...
When a full stroke is done, relief the foot pedal and the tool will go back to its starting position and the hose grip system will open. Check the skiving result. Picture 1 Hydroscand Machine AB Kungsvägen 22 Phone: +46(0) 225-57330 S-783 35 SÄTER...
Then close the box and try to start the machine again. When the machine fails to start you must contact an electrician. Hydroscand Machine AB Kungsvägen 22 Phone: +46(0) 225-57330 S-783 35 SÄTER...
Page 10
A semi-automatic PLC-controlled skiving machine, quick, reliable and easy to use. A centering system assures that the hose is correctly aligned during the entire skiving and inserting process. PowerSkive 5-50 can also be used for insert of fittings. Advantages: - PLC-controlled...
Page 18
9 METAL WORK FILTER FIL 100 1/ 4" 20 SAC 3280008 Ritad av Kund 10 METAL WORK PRESSUR SWITCH PSM 10/ R18 T4D 90990641 Hydroscand Machine AB 11 METAL WORK SOFT START VALVE APR 100 1/ 4" 3267051 Datum Ritningsnr. Rev.
Page 22
T0057_Gaffelhuvud -2st. D17047_Stång Mutter HM, M16 -2st (ML6M 16_Mutter) Sprint -2st 2 Mutter HM, M16 - 4 Nut HM, M16 - 4, Product Grade A, type 2 - NF E 25-405 2 T0057_Gaffelhuvud Articulation for rod end of a cylinder with a 63mm bore 1 D17047_Stång D17047_Stång, configuration:Default ITEM NO.
Page 25
Rev. No. Revision information Checked date ITEM NO. QTY. PART NO. DESCRIPTION S17011_Motorplatta S17011_Motorplatta, configuration:Default E0050_Glidbussning MC6S8x25_Skruv PART LIST Drawn by ÅE Date 2001-08-16 QTY. Material SKRUVAR FÖR GLIDBUSSNING ÅTDRAGES EFTER ATT SLÄDEN Scale Approved by Part name Släde MONTERATS PÅ MONTERADE AXLAR Drw.
Need help?
Do you have a question about the PowerSkive 5-50 and is the answer not in the manual?