Other Maintenance
The remote air cooled condenser coil must be
cleaned occasionally to keep the system operating
at high efficiency.
·
Remove any large debris from the outside of the
coil.
·
Vacuum accumulated dust.
·
Wash out the coils with water.
Caution: Do NOT use excessive water pressure as
that will bend the fins.
·
Straighten any damaged fins with a fin comb.
·
If the coils have become coated with grease, a
coil cleaner will have to be used to wash the
coils.
Disconnect power to the condensing unit and
remove the condenser top.
·
Inspect the fan blade to be sure it is not cracked
and is clean.
Return the condenser top to its original position
and reconnect the power supply.
Prodigy Eclipseä 600, 800, 1000
Moving Parts Hazard
Rotating fan blade can
cause cuts
Disconnect electrical power
before removing condenser
top or fan guard.