GE DBL333 Owner's Manual page 17

Dryers owner's manual
Table of Contents

Advertisement

Remove the screws securing the terminal block
1
access cover and the strain relief mounting
bracket located on the back of the dryer upper
corner.
Install a UL-approved strain relief into the power
2
cord entry hole of the mounting bracket. Use
a strain relief which attaches to the mounting
bracket with a nut. Finger-tighten the nut only
at this time.
Thread a UL-approved 30A, 240V, 3 #10 AWG
3
minimum copper conductor power cord through
the strain relief.
4-Wire System for Electric Dryers—MUST be used for Mobile Home Installations
Remove the screws securing the terminal block
access cover and the strain relief mounting
bracket located on the back of the dryer upper
corner.
Install a UL-approved strain relief in the entry
hole of the mounting bracket. Use a strain relief
which attaches to the mounting bracket with a
nut. Finger-tighten the nut only at this time.
Remove the green neutral ground wire from the
3
green ground screw located above the terminal
block.
Thread a UL-approved 30A, 240V, 4 #10 AWG
4
minimum copper conductor power cord through
the strain relief.
Attach the green power cord ground wire to the
5
cabinet with the green ground screw.
Attach the white (neutral) power cord
6
conductor from the power cord and the green
ground wire from the dryer harness to the silver-
colored center terminal on the terminal block.
Tighten the screw securely.
Attach the power cord neutral (center wire)
4
conductor to the silver-colored center terminal
on the terminal block. Tighten the screw
securely.
Attach the remaining two power cord outer
5
conductors to the outer brass-colored terminals
on the terminal block. Tighten both screws
securely.
WARNING: Do not make a sharp bend or crimp
wiring/conductor at connections.
Reattach the strain relief mounting bracket to
6
the back of the dryer with two screws. Tighten
screws securely.
Tighten the screws securing the cord restraint
7
firmly against the power cord.
Tighten the strain relief nut securely so that the
8
strain relief does not turn.
Reinstall the terminal block access cover.
9
Attach the red and black power cord conductors
7
to the outer brass-colored terminals on the
terminal block.
WARNING: Do not make a sharp bend or crimp
wiring/conductor at the connections.
Tighten the screws securing the cord restraint
8
firmly against the power cord.
Tighten the strain relief nut securely so the
9
strain relief does not turn.
Reinstall the terminal block access cover.