Page 1
All manuals and user guides at all-guides.com Vax careline 0870 6061248 Bagless upright Vax model number: VZL-6015 VZL-6016 VZL-6015A VZL-6016A VZL-6015AA VZL-6016AA Please read carefully before using this cleaner. www.vax.co.uk Always fully extend the mains cable before use. Retain for future reference.
Page 2
VZL-6016AA only) other hard flooring. See page 5 details. Vax will not be held responsible for damage to 27 Additional stretch hose (VZL-6016, VZL-6016A hard floors, including lino, if the customer fails and VZL-6016AA only) to switch the brush bar off on these surfaces.
If the supply cord or plug is cleaner. damaged, return the vacuum cleaner to a Vax Authorised Service Agent or suitably qualified IMPORTANT: Cleaning filters regularly improves person for examination, repair or adjustment.
All manuals and user guides at all-guides.com www.vax.co.uk 3. How to assemble Attach Upper Housing Remove dirt cup (A) from upper housing (B) by pressing dirt cup release button (C) and pivoting cup out. Set dirt cup aside (Fig.3/1). Fig.3/4 Place bottom of dirt container into cleaner body first.
Page 5
All manuals and user guides at all-guides.com Vax Careline 0870 606 1248 After ends are connected, pull on plug to make sure it is securely attached. Push firmly until you hear a snap or click Fig.3/7 Position hose over rack (A) and into hose tube (B) Fig.3/10...
All manuals and user guides at all-guides.com www.vax.co.uk Position Tools 4. How to operate Place smaller diameter end of extension tube (A) into On/Off Switch bottom of rack. Snap extension tube into clip at top. Repeat with other extension tube.
Page 7
All manuals and user guides at all-guides.com Vax Careline 0870 606 1248 Carrying Cleaner The cleaner can also be moved by using the carrying handle (Fig.4/6). Fig.4/3 Telescopic Handle The telescoping handle includes adjustable settings to Fig.4/6 various heights for user comfort. The handle is designed...
Page 8
All manuals and user guides at all-guides.com www.vax.co.uk Settings For maximum cleaning performance, the following carpet height settings are recommended Fig.4/9 (Fig.4/9): NOTE: If the cleaner is difficult to push, turn knob to the next higher setting. Fig.4/11 • Higher settings: for very deep pile carpet, where easier...
Page 9
All manuals and user guides at all-guides.com Vax Careline 0870 606 1248 Select Proper Tool Combination tool: use with brush for carved furniture, table tops, books, lamps, lighting fixtures, venetian blinds, baseboards, shutters, and registers. Remove brush to clean upholstered furniture, draperies, mattresses, clothing, and carpeted stairs.
Page 10
All manuals and user guides at all-guides.com www.vax.co.uk 5. Dirt container & filters: removal & replacement NOTE: Familiarize yourself with these home maintenance tasks as proper use and care of your cleaner will ensure continued cleaning effectiveness. Emptying the Dirt Container Empty the dirt cup before the dirt reaches the fill line (A) (Fig.5/1).
Page 11
All manuals and user guides at all-guides.com Vax Careline 0870 606 1248 Remove dirt container as described above. Twist filter assembly counterclockwise. Remove assembly from dirt container (Fig.5/6). Fig.5/8 Cleaning the HEPA Final Filter IMPORTANT: Disconnect cleaner from electrical Fig.5/6 outlet.
All manuals and user guides at all-guides.com www.vax.co.uk 6. Maintenance Replacing Flat Belt Disconnect cleaner from electrical outlet. Replacing the Headlight Place handle in low position and turn cleaner over so Removing lens bottom side is facing up. Disconnect cleaner from electrical outlet.
Page 13
All manuals and user guides at all-guides.com Vax Careline 0870 606 1248 Disconnect cleaner from electrical outlet. Turn carpet height adjustment knob to lowest setting. Turn cleaner over and remove bottom plate. Lift up brushbar and slide V-belt (A) off brushbar (Fig.6/9).
Page 14
All manuals and user guides at all-guides.com www.vax.co.uk Fig.6/11 Fig.6/14 Grasp brushbar firmly and fit it into position by first Remove brushbar including end plates (A) and discard. sliding end opposite the belt into the rectangular slot (A) Inspect belt to ensure that it is in good condition. If belt on side of cleaner.
Page 15
All manuals and user guides at all-guides.com Vax Careline 0870 606 1248 Grasp turbine (A) and pull firmly to remove. Remove belt from turbine pulley (B). Replace with new belt (Fig.6/20). Fig.6/17 Replace and tighten screws. Fig.6/20 To replace bottom plate, insert the four tabs on edge of With flat sides of turbine retainers (A) pointing down, slide bottom plate into slots on front of tool.
All manuals and user guides at all-guides.com www.vax.co.uk 7. Clearing blockages Checking Under Hood Turn cleaner OFF and unplug. IMPORTANT: Disconnect cleaner from electrical Remove hood, belt and brushbar as described in previous outlet before attempting to clear blockages. section. Look into opening (A) for blockages and remove Low suction or pick up may be due to a blockage in the (Fig.7/3).
No electricity in wall outlet. number of the carpet cleaner before calling. There are Solution: Check fuse or breaker. over 400 approved Vax Service Agents in the UK. For the Cause: Blown fuse/tripped breaker. nearest Service Agent, please call the Vax Careline.
All manuals and user guides at all-guides.com www.vax.co.uk 10. Technical Specification Voltage: 220 – 240V ~50Hz Wattage: 1500W Capacity: 2.6l Filters: Washable pre-motor filter assembly HEPA post-motor assembly Cord Length: 8.3m Weight: 10.68kg Subject to technical change without notice. technical specification...
Page 19
All manuals and user guides at all-guides.com Vax Careline 0870 606 1248 This page has been left intentionally blank.
Page 20
All manuals and user guides at all-guides.com EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: Vax Limited, hereby on our own responsibility, declare that the VZL-6015 Mach 5 range and VZL-6016 Mach 6 range upright vacuum cleaners are manufactured in compliance with the following Directives:...