All manuals and user guides at all-guides.com Vax careline 0844 412 8455 Bagless upright Vax model number: U90-M5 Series U90-M6 Series PLEASE NOTE: some parts may vary according to model. Please check inside flap of box for more details. Please read carefully before using this cleaner.
Page 2
See page 5 details. 27 Additional stretch hose (Some models only) Vax will not be held responsible for damage to hard floors, including lino, if the customer fails to switch the brush bar off on these surfaces.
If the supply cord or plug is cleaner. damaged, return the vacuum cleaner to a Vax Authorised Service Agent or suitably qualified IMPORTANT: Cleaning filters regularly improves person for examination, repair or adjustment.
9/9/09 16:45 Page 4 All manuals and user guides at all-guides.com vax.co.uk 3. How to assemble Attach Upper Housing Remove dirt cup (A) from upper housing (B) by pressing dirt cup release button (C) and pivoting cup out. Set dirt cup aside (Fig.3/1).
Page 5
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 5 All manuals and user guides at all-guides.com Vax Careline 0844 412 8455 After ends are connected, pull on plug to make sure it is securely attached. Push firmly...
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 6 All manuals and user guides at all-guides.com vax.co.uk Position Tools 4. How to operate Place smaller diameter end of extension tube (A) into On/Off Switch bottom of rack. Snap extension tube into clip at top.
Page 7
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 7 All manuals and user guides at all-guides.com Vax Careline 0844 412 8455 Carrying Cleaner The cleaner can also be moved by using the carrying handle (Fig.4/6). Fig.4/3 Telescopic Handle The telescoping handle includes adjustable settings to Fig.4/6...
Page 8
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 8 All manuals and user guides at all-guides.com vax.co.uk Settings For maximum cleaning performance, the following carpet height settings are recommended Fig.4/9 (Fig.4/9): NOTE: If the cleaner is difficult to push, turn knob to the next higher setting.
Page 9
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 9 All manuals and user guides at all-guides.com Vax Careline 0844 412 8455 Select Proper Tool TurboTool: may be used for upholstered furniture, draperies, mattresses, clothing, automobile interiors, and carpeted stairs.
Page 10
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 10 All manuals and user guides at all-guides.com vax.co.uk 5. Dirt container & filters: removal & replacement NOTE: Familiarize yourself with these home maintenance tasks as proper use and care of your cleaner will ensure continued cleaning effectiveness.
Page 11
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 11 All manuals and user guides at all-guides.com Vax Careline 0844 412 8455 Remove dirt container as described above. Twist filter assembly counterclockwise. Remove assembly from dirt container (Fig.5/6).
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 12 All manuals and user guides at all-guides.com vax.co.uk 6. Maintenance Replacing Flat Belt Disconnect cleaner from electrical outlet. Replacing the Headlight Place handle in low position and turn cleaner over so Removing lens bottom side is facing up.
Page 13
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 13 All manuals and user guides at all-guides.com Vax Careline 0844 412 8455 Disconnect cleaner from electrical outlet. Turn carpet height adjustment knob to lowest setting. Turn cleaner over and remove bottom plate.
Page 14
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 14 All manuals and user guides at all-guides.com vax.co.uk Fig.6/11 Fig.6/14 Grasp brushbar firmly and fit it into position by first Remove brushbar including end plates (A) and discard.
Page 15
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 15 All manuals and user guides at all-guides.com Vax Careline 0844 412 8455 Grasp turbine (A) and pull firmly to remove. Remove belt from turbine pulley (B). Replace with new belt (Fig.6/20). Fig.6/17 Replace and tighten screws.
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 16 All manuals and user guides at all-guides.com vax.co.uk 7. Clearing blockages Checking Under Hood Turn cleaner OFF and unplug. IMPORTANT: Disconnect cleaner from electrical Remove hood, belt and brushbar as described in previous outlet before attempting to clear blockages.
Any queries or concerns about using the Vax, call the Cause: Not properly plugged into wall outlet. Vax Careline. Please make a note of the serial number and Solution: Plug in firmly. model number of the carpet cleaner before calling. For Cause: No electricity in wall outlet.
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 18 All manuals and user guides at all-guides.com vax.co.uk 11. Technical Specification Voltage: 220 – 240V ~50Hz Wattage: 1500W Capacity: 2.6l Filters: Washable pre-motor filter assembly HEPA post-motor assembly...
Page 19
U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016 9/9/09 16:45 Page 19 All manuals and user guides at all-guides.com Vax Careline 0844 412 8455 This page has been left intentionally blank.
Page 20
All manuals and user guides at all-guides.com EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: Vax Limited, hereby on our own responsibility, declare that the Mach 5 series and Mach 6 series upright vacuum cleaners are manufactured in compliance with the following Directives:...