Maintenance; Output - Furuno INTERFACE UNIT IF-2500 Operator's Manual

Interface unit
Hide thumbs Also See for INTERFACE UNIT IF-2500:
Table of Contents

Advertisement

Maintenance

Self test 1
The unit performs an internal self-check in
the following sequence each time power is
turned on.
1. LEDs CR7 to CR10 blink twice every 2
seconds.
2. ROM and RAM are tested.
3. LED CR6 blinks every second for normal
operation. If an error is detected during
the test, the corresponding LED is turned
on.
When CR7 is on, ROM is defective.
When CR8 is on, RAM is defective.
Self test 2
The test requires an external loop to check
I/O. Follow the steps below to carry out the
test.
1. Set the DIP switch #4 of S1 to the ON
position.
2. Temporarily disconnect input and output
connectors J2 and J4.
3. Construct a pair of short connector
assemblies as below.
For J4, J5, J6 ,J7 and J8
XH4P
1
RS422_OUT_A
2
RS422_OUT_B
3
NC
4
GND
For J9
XH5P
1
RS422_OUT_A
2
RS422_OUT_B
3
NC
4
NC
5
GND
Short connector assy
4. Connect the XH6P-XH4P short connector
assy. between J2 and J4.
5. Confirm that each LED lights according
to equipment status as follows:
5. Remove the connector from J4 and plug
6. Remove the XH6P-XH5P short
J2
XH6P
1
NC
2
NC
3
RD_H
RD_C
4
NC
5
GND
6
J2
XH6P
1
NC
2
NC
3
RD_H
RD_C
4
NC
5
The relay contact signal output is turned on
GND
6
and off alternately every second during the
test.
Fuse replacement
If the fuse blows, find the cause of the
problem before replacing it. Do no use a fuse
rated more than 0.5A, since it may cause
more serious damage to the equipment.
5
CR2
Lights when receiving NMEA data
from J2.
CR4
Lights when sending NMEA data
to J4 thru J9.
CR6
Blinks every second.
CR7
Lights when ROM error is
detected.
CR8
Lights when RAM error is
detected.
CR9
Lights when SIO error is detected.
CR10
Normally off.
it into J5, J6, J7 and J8 successively,
confirming that CR2 and CR9 light as
below for each port. Then, remove the
XH6P-XH4P short connector assy., plug
in the XH6P-XH5P short connector assy.
between J2 and J9, and confirm that CR2
and CR9 light as below.
CR2
Lights when receiving NMEA data
at J2.
CR9
Lights when SIO error is detected.
connector assy. Plug in the XH6P-XH4P
short connector assy. between J3 and J4,
J5, J6, J7 and J8 successively. Confirm
that LEDs light or blink as below.
Remove the XH6P-XH4P short
connector assy., plug in the XH6P-XH5P
short connector assy. between J3 and J9
and confirm that the LEDs light or blink
as below.
CR3
Lights when receiving NMEA data
at J3.
CR4
Lights when sending NMEA data
to J4 thru J9.
CR6
Blinks every second.
CR9
Lights when SIO error is detected.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTERFACE UNIT IF-2500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents