MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 2 Indice 1 Lista de Embalaje y Accesorios ........................4 1.1 Contenido estándar del paquete ..............................4 1.2 Accesorios ....................................4 2 Seguridad ..............................5 2.1 Riesgos a los que está sometido el operador ..........................6 2.2 Cualificación del personal ................................6 2.3 Utilización del equipo ................................6 2.4 Modificaciones ..................................6...
Page 3
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 3 Index 1 Packing List and Accessories ........................30 1.1 Package contents ...................................30 1.2 Accessories ....................................30 2 Safety .................................31 2.1 Risks to which the operator is exposed .............................32 2.2 Staff qualification ..................................32 2.3 Equipment use ..................................32 2.4 Modifications ..................................32...
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 4 1 Lista de Embalaje y Accesorios 1.1 Contenido estándar del paquete • Espectrofotómetro • Cable conexión red eléctrica • Manual de instrucciones • Software de comunicación con PC •...
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 5 2 Seguridad Los espectrofotómetros UV-2005 incluyen las medidas de seguridad adecuadas para su utilización en un laboratorio. El aparato descrito en este manual está diseñado para ser utilizado por técnicos con una formación adecuada.
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 6 Obligatorio el uso de protección de los ojos. Es obligatorio el uso de gafas de seguridad o protección facial completa para realizar la operación descrita. En el apartado «1.2 Accesorios»...
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 7 3 Principio de Funcionamiento El equipo UV-2005 se compone de cinco partes: • Una lámpara halógena y otra de deuterio como fuentes de luz. • Un monocromador para seleccionar la longitud de onda deseada y eliminar las radiaciones de segundo orden.
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 8 4 Instalación Una vez desembalado el equipo, compruebe que está en buen estado. Conserve el embalaje durante unos días. 4.1 Emplazamiento Sitúe el equipo en una superficie plana, nivelada, estable, adecuada al peso del equipo y fuera de la luz solar directa.
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 9 5 Operación El panel de control permite seleccionar las funciones del equipo e informa del estado actual de funcionamiento. Una vez enchufado a la red, pulsando el interruptor principal, el equipo se pone en marcha (ON).
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 10 5.3 Funcionamiento Básico - Coloque la cubeta del blanco en el portacubetas. - Pulse la tecla [ZERO] para calcular el blanco. Nota: 1. Si la solución de referencia es demasiado espesa, la energía será baja. 2.
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 11 6 Análisis de Muestras Se proporcionan tres métodos de análisis: el Modo Básico, el Modo Cuantitativo y el Modo Cinético. 6.1 Modo Básico Coloque la cubeta de blanco en el portacubetas. En el menú principal (último en la Fig.
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 12 6.2 Modo Cuantitativo Incluye dos métodos de test: Curva Estándar y Factor. En el primer método, se puede establecer una curva estándar utilizando muestras estándar de una concentración conocida.
Page 13
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 13 Pulse [SET] en la pantalla de pre-test para ir a la pantalla de parámetros (Fig.12). Antes de realizar el test deberá establecer las Unidades, el Número de muestras estándar y la Concentración de estas.
Page 14
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 14 Establecer la Concentración de los Estándares Antes de realizar este paso, deberá calcular el blanco. Coloque la cubeta en el por- tacubetas y pulse [ZERO]. Mueva el cursor hasta Concentration y pulse [ENTER].
Page 15
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 15 La nueva ecuación de curva establecida se mostrará al final del grupo. Se pueden guardar hasta un total de 200 ecuaciones de curva. Mueva el cursor hasta la ecuación que desee pulsando [»] y [«]. Si desea volver a la pantalla de ajuste previa, pulse [ENTER].
Page 16
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 16 2-2. Método Concentración por Factor Si conoce la ecuación de la curva estándar, podrá utilizar este método. Mueva el cursor hasta Coefficient (Concentración por Factor) pulsando [»] y [«], y después pulse [ENTER], e irá...
Page 17
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 17 Establecer Parámetros Pulse [SET] en la pantalla de pre-test del método de concentración por factor, y deberá establecer 3 parámetros antes de realizar la prueba. (Fig. 24) Figura 24 Establecer Factor K Mueva el cursor hasta Coefficient K (Factor K) pulsando [»] y [«], y después...
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 18 Establecer Unidad de Concentración Mueva el cursor hacia Conc. Unit (Unidad de Concentración) pulsando [»] y [«], y después pulsando [ENTER]. (Fig. 27) Mueva el cursor hasta la unidad que desea seleccionar y pulse [ENTER].
Page 19
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 19 Establecer la Longitud de Onda Pulse [GOTO] en la pantalla de pre-test del modo cinético, e introduzca le longitud de onda de la prueba pulsando el teclado numérico. (Fig.30). Figura 30 Establecer Parámetros Pulse [SET] en la pantalla de pre-test del modo cinético, y deberá...
Page 20
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 20 Establecer Tiempo Total Mueva el cursor hasta Total Time (Tiempo Total) pulsando [»] y [«], y después [ENTER]. (Fig.33) Introduzca el nuevo tiempo de prueba total pulsando el teclado numérico seguido de [ENTER], y de esta manera volverá...
Page 21
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 21 Introduzca el nuevo valor inferior mediante el teclado numérico y seguidamente pulse [ENTER], de este modo volverá a la pantalla de ajustes cinéticos. Si no desea cambiar el valor establecido la última vez, pulse [ENTER] o [RETURN] directamente.
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 22 Impresión de Datos Pulse [PRINT] en el display inferior de la Fig.38, y se imprimirán los datos. Después de imprimir, todos los datos se borrarán de la pantalla y de la RAM. También se pueden borrar los datos si selecciona [CLEAR].
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 23 Nota: La lámpara D2 necesita unos 20 segundos para calentarse antes de encenderse! (Fig. 42) Se recomienda apagar la lámpara D2 cuando no se utilice, después de realizar un pre-test.
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 24 7.4 Configurar Tiempo y Fecha Mueva el cursor hasta Time and Date (Tiempo y fecha) pulsando [»] y [«] en la pantalla de configuración de Utilidades, y después pulse [ENTER] para ir a la pantalla de ajustes de tiempo y fecha.
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 25 El tiempo de calibración es de aproximadamente 1.5 minutos. 7.7 Gestión de la Vida de la Lámpara Mueva el cursor hacia Lamp Life (Vida de la Lámpara) pulsando [»] y [«] en la pantalla de configuración de Utilidades, y después pulse [ENTER].
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 26 8 Mantenimiento 8.1 Sustitución de lámparas Lámpara de tungsteno-halógeno Apague y desenchufe el equipo. Retire los cuatro tornillos de los lados del espectrofotómetro. Retire la varilla de selección de muestra desenroscándola en sentido antihorario.
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 27 Desenroscar los dos tornillos de la Cámara de la lámpara y quitar la cubierta. Atención La cubierta puede estar caliente, asegúrese de usar guantes Figura I Conector Desconectar el conector de 3 hilos tirando de él hacia arriba.
Fase, Neutro, Tierra (sección 1mm Peso (Neto): 14 Kg Medidas: Fondo x Ancho x Alto 370 x 470 x 180 mm Modelo UV 2005 Rango longitud onda 190-1100nm Ancho de banda espectral Sistema óptico Un solo haz con red de 1200 líneas/mm Precisión de longitud onda...
Page 29
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 29 English Version .P. SELECTA s.a. Ctra. NII Km 585.1 Abrera 08630 (Barcelona) España Tel 34 93 770 08 77 Fax 34 93 770 23 62 e-mail: selecta@jpselecta.es - website: http://www.jpselecta.es...
Page 30
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 30 1 Packing List and Accessories 1.1 Package contents • Spectrophotometer • Power connection cable • Instructions manual • PC communication software • Equipment protection cover •...
Page 31
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 31 2 Safety Spectrophotometers UV-2005 include the safety measures suitable for a safety ope- ration in a laboratory. This equipment has been designed to be used by technicians who have been quali- fied for its use.
Page 32
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 32 Eyes protection use compulsory It is compulsory the use of safety glasses or complete facial protection to do the described operation. A recommended model is indicated in the «1.2 Accessories» section. Important information •...
Page 33
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 33 3 Operating Principle UV-2005 equipment is composed of five parts: • An halogen lamp and a deuterium lamp as light sources. • A monochromator to select the wavelength and to eliminate second order radia- tions.
Page 34
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 34 4 Installation Once the equipment is unpacked, check it is all right. Preserve the packing for some days. 4.1 Location Place the equipment over a flat, levelled and stable surface, suitable for the equipment weight and not exposed to direct sunlight.
Page 35
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 35 5 Operation The control panel allows the equipment functions selection and informs about the current operating status. Once plugged to the mains, press the main switch and the equipment will start (ON). Let it heat up for 20 minutes before taking any reading.
Page 36
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 36 5.3 Basic Operation Blank - Push the blank cuvette into the light path. - Press the key [ZERO] for blanking. Note: 1. If the reference solution is too thick, the energy will be low. 2.
Page 37
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 37 6 Analyze Sample We provide three test methods, which are basic mode test, quantitative mode and kinetics mode. 6.1 Basic Mode Push the blank cuvette into the light path. In the main menu (the last one of Fig. 3), move the cursor onto “Basic mode”...
Page 38
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 38 Enter Quantitative Mode Move the cursor onto the Quantitative Mode, and press [ENTER] to go into the method choosing interface (Fig. 9). 2-1. Standard Curve Method It’s a method to establish a standard curve by measuring a group of standard samples.
Page 39
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 39 Choose Unit of Standard Samples Move the cursor onto “Unit” by pressing [»] and [«], followed by [ENTER], 8 units are under your selection (Fig 13). Move the cursor onto the unit you need, then press [ENTER].
Page 40
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 40 sample 2, the operation is the same as sample 1. Repeat the operation step by step, till the last sample finished, and then it goes back to the setting screen.
Page 41
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 41 Press [RETURN] to go back to pre-testing interface. Note: If you want to delete an equation, move the cursor onto it, and just press [CLEAR]. Test and Print When you have selected the equation, press [START/STOP] to go into testing interface in pre-testing interface.
Page 42
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 42 2-2. Coefficient Method If you know the standard curve equation, you can use this method to test. Move the cursor onto the Coefficient by pressing [»] and [«], and then press [ENTER], it goes into the formula selecting screen.
Page 43
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 43 Set Parameters Press [SET] in the coefficient method pre-testing screen, and 3 parameters should be set before testing. (Fig. 24) Figure 24 Set Coefficient K Move the cursor on Coefficient K by pressing [»] and [«], followed by [ENTER].
Page 44
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 44 (Fig. 27) Move the cursor on the unit you need, then press [ENTER]. You can also press the number ahead of the unit directly by means of the numeric keypad. Press [RETURN] to go back to the pre-testing screen.
Page 45
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 45 Set Wavelength Press [GOTO] in the kinetics pre-testing screen, and input the testing wavelength by pressing the numeric keypad (Fig.30). Figure 30 Set Parameters Press [SET] in the kinetics pre-testing screen, and 5 parameters should be set before testing.
Page 46
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 46 Move the cursor onto Total Time by pressing [»] and [«], followed by [ENTER]. (Fig.33) Input the new total test time by pressing the numeric keypad followed by [ENTER], and it will return to the kinetics setting screen.
Page 47
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 47 followed by [ENTER] (Fig.36) Input the new lower value by pressing the numeric keypad and then press [ENTER], and it will return to the kinetics setting screen. If you don’t want to change the value being set last time, press [ENTER] or [RE- TURN] directly.
Page 48
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 48 Data Print Press [PRINT] in the down display of Fig.38, and the data will be printed. After printing, the data will be deleted from the screen and RAM. You can also delete the data if you press [CLEAR].
Page 49
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 49 7.2 Set W Lamp Move the cursor onto W Lamp on/off by pressing [»] and [«] in utility setting screen, and then press [ENTER] to go into W lamp controlling screen. (Fig. 43) Move the cursor on OFF to shut off the W lamp by pressing [»] and [«] followed by [ENTER].
Page 50
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 50 In the time and date setting screen, press [»] and [«] to move the cursor. You can set them by pressing the numeric keypad followed by [ENTER]. The range of year is 0 - 99, month is 0 - 12, day is 1 - 31, hour is 0 - 24, minute is 0 - 59, week is 1 - 7, other number is invalid.
Page 51
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 51 lamp. (Fig. 49) When the used time of D2 lamp is higher than 1000 hours, replacing a new one is strongly recommended. When the used time of W lamp is higher than 1000 hours, replacing a new lamp is strongly recommended.
Page 52
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 52 8 Maintenance 8.1 Lamps replacing Tungsten-halogen lamp Switch off and unplug the equipment. Remove the four screws from the spectrophotometer sides. Remove the sample selection bar unscrewing counter clock. Remove the equipment cover very carefully and place it to the right.
Page 53
INSTRUCTION MANUAL CODE 80243 REV A January/11 (It can be modified without notice) Page: 53 Unscrew the two lamp chamber screws and remove the cover. Attention The cover could be very hot, remember to use gloves! Fig. I Connector Unplug the 3 wire connector by pulling it up. Loosen and remove the two white screws (Fig.
Page 54
Network connection cable: Phase, Neutral, Earth (section 1mm Weight (Net): 14 Kg Dimensions: Depth x Width x Height 370 x 470 x 180 mm Model UV 2005 Wavelength range 190-1100nm Spectral wavelength Optical system one beam with 1200 lines/mm net Wavelength accuracy ±...
Page 55
ESPAÑA Declara que los equipos / Declares that the equipments: Modelo / Model: Código / Code: 4120020 Espectrofotómetro / Spectrophotometer UV 2005 Cumple las siguientes directivas europeas / Meet the following Directives: 73/23/CEE Directiva de seguridad eléctrica Electrical safety 89/336/CEE Directiva de compatibilidad electromagnética...
Page 56
MANUAL DE INSTRUCCIONES CODIGO 80243 REV A Enero /11 (Sujetas a modificaciones sin previo aviso) Pag.: 56 .P. SELECTA s.a. Ctra. NII Km 585.1 Abrera 08630 (Barcelona) España Tel 34 93 770 08 77 Fax 34 93 770 23 62 e-mail: selecta@jpselecta.es - website: http://www.jpselecta.es...
Need help?
Do you have a question about the UV 2005 and is the answer not in the manual?
Questions and answers