Keep hands and/or other objects away from the
antenna.
2. Release the switch.
A single flash indicates a passed test. If this is not the
result, refer to the error codes.

9.2.1.1 Error codes (flashes)

If the self-test detects an error in the EPIRB module, one or more of the
following will occur:
Number of
Error codes
Flashes:
2
Low power on 406MHz transmitter
3
Low battery voltage
4
Low power on 121.5MHz transmitter
5
PLL on 406MHz transmitter out of lock
6
PLL on 121.5MHz transmitter out of lock
EPIRB module not programmed or programming not
7
complete
Table 5 Tron 40VDR self-test error codes (flashes)