Inspection - jotron Tron 40VDR Capsule User Manual

Hide thumbs Also See for Tron 40VDR Capsule:
Table of Contents

Advertisement

The battery must be replaced and changed at a Jotron SBM
Every 4-5
authorized location (to be GMDSS compliant). Test in accordance
years
with MSC. 1039 SBM. The SMB is decided by the flag state
administration.
Every 10
Jotron recommends that the EPIRB and FB-40 float free bracket
years
are replaced at this time.
Table 4 Tron 40VDR maintenance requirements
9.1

Inspection

The lifetime of any equipment depends on how well you take care of it.
Inspect both the Tron 40VDR and the FB-40 float free bracket for defects.
To inspect, do the following:
1. Ensure the bracket cover is not blocked (this hinders the release
functionality of the EPIRB).
2. Ensure the EPIRB and bracket are clean (no paint, oil and other
chemicals).
3. Verify the lanyard is attached (on the EPIRB and not the vessel)
4. Verify the expiry date of EPIRB battery.
5. Verify the expiry date of HRU (month/year)