MAX 20W LED FLOOD LIGHT
RLEDF20W-24
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or
use of this prodcut, consult a competent electrician
Product technical information and specification may change over time without prior notification
For the latest technical information please visit our web site WWW. ledgrouprobus. com or robusdirect. com
Specifications
RLEDF20W-24
Model No. :
Power (W):
20W
Supply voltage:
220-240V~ 50/60Hz
3000K
CCT:
1500lm
Lumen:
CRI:
70
PF:
≥0.9
35,000 Hours
Average Lamp Life:
Safety Class:
Class I , Must be Earthed.
-15 º C <Ta < 40 º C
Ambient temp:
IP65
Ingress Protection:
Depth (mm):
105mm
Width(mm):
180mm
160mm
Height (mm):
1.18Kg
Weight (kg):
Warranty:
3 years
EN60598-2-5:1998, EN62493:2010,
EN60598-1:2008+A11:2009,
EN61347-2-13:2006,
Projection distance:
12m - 18m
Max projection area:
18m x 10m
Mounting height:
2.5m - 6m
Information for the Product user:
1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with
crossed out wheelie bin symbol).
2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre for waste electrical
equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
3. This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is
separated from normal household waste and recycled in the WEEE chain
4. The "crossed out wheelie bin symbol" on a product indicates this equipment must not be disposed of in normal household waste, but should be
disposed of according to local WEEE regulations
The Installation must be carried out by an electrician
LED Group
Western Retail Park
Nangor Road
Dublin 12
Ireland
Issue 1 190814
All manuals and user guides at all-guides.com
Note:
Tel: +353 1 7099000
Fax: +353 1 7099060
Email: info@led.ie
Website: www.led.ie
INSTRUCTION MANUAL
Installation:
1.Ensure mains supply is switched off before commencing
work.
2.Select suitable location for luminaire,
3.Remove bracket from luminaire, mark wall with
appropriate fixing positions. Before drilling, ensure that the
hole does not impinge on pipe work, cables or other
building services.
4.Mount bracket on wall and re-attach luminaire
5.The luminaire is supplied with 1m of rubber cable. Using
suitable IP rated enclosure terminate Brown (Live), Blue
(Neutral) and Green/ Yellow (Earth) to switch supply.
6. This product has no user serviceable parts. If any part is
damaged, disconnect from mains and discontinue use.
Note: No "fixings screws provided", please use appropriate
fixings screws.
ISO 9001:2008
Q UAL IT Y ASSU RE D CO MPANY