Direct Electrical Connection To The Circuit Breaker, Fuse Box Or Junction Box - Frigidaire 318201724 Installation Instructions Manual

30" electric range
Table of Contents

Advertisement

Available languages

Available languages

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction box, use flexible, armored or nonmetallic
sheathed copper cable (with grounding wire). Supply a U.L.
listed strain-relief at each end of the cable. At the appliance
end, the cable goes through the Direct Connection Hole (see
Figure 4) on the Cord Mounting Plate. Wire sizes (copper
wire only) and connections must conform to the rating of the
appliance.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire (see
Figure 5):
1. Be sure that no power is supplied on the cable from
residence.
2. Follow instructions on previous page for Four Conductor
Wire Connection to Range (Fig. 4).
3. In the circuit breaker, fuse box or junction box (Fig. 5):
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Cable from Residence
Neutral
(white) Wire
Red
Wires
Green
(or Bare Copper)
Wire
Cable from
Appliance
NOTE: Be sure to remove the
supplied grounding strap.
3-Wire (Grounded Neutral) Electrical System (Example:
Junction Box)
Black
Wires
Junction
Box
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
Figure 5
Where local codes DO NOT permit connecting the
appliance-grounding conductor to the neutral (white)
wire, or if connecting to 4-wire electrical system (see
Figure 6):
1.
Be sure that no power is supplied on the cable from
residence.
2.
Follow instructions on previous page for Four Conductor
Wire Connection to Range (Fig. 4).
3.
In the circuit breaker, fuse box or junction box (Fig. 6):
a) Connect the white appliance cable wire to the neutral
(white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding wire to
the grounding wire of the circuit breaker, fuse box or
junction box.
Cable from Residence
Green (or Bare
Copper) Wire
Red
Wires
Green (or Bare
Copper) Wire
Junction
Box
NOTE: Be sure to remove the
supplied grounding strap.
Figure 6 – 4-Wire Electrical System
(Example: Junction Box)
4
White Wire
Black
Wires
White Wire
U.L.-listed Conduit
Connector (or CSA
Cable from
listed)
Appliance

Advertisement