Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box
or Junction
Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction
box, use flexible, armored or nonmetallic
sheathed copper cable (with grounding
wire). Supply a U.L.
listed strain-relief
at each end of the cable. At the appliance
end, the cable goes through the Direct Connection Hole (see
Figure 4) on the Cord Mounting
Plate. Wire sizes (copper
wire only) and connections must conform to the rating of the
appliance.
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutral
(white)
wire (see
Figure 5):
1. Be sure that no power is supplied on the cable from
residence.
2. Follow instructions on previous page for Four Conductor
Wire Connection to Range (Fig. 4).
3. In the circuit breaker, fuse box or junction box (Fig. 5):
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Cable from Residence
Neutral
(white) Wire
_
:::_
k_idr_
_
Green
(or Bare Copper)
Wire
Cable from
Appliance
--
Black
Wires -
Junction
Box
Wire
U.L.-listed Conduit
Connector (or CSA
listed)
NOTE: Be sure to remove the
supplied grounding strap.
Figure 5
3-Wire (Grounded
Neutral)
Electrical
System (Example:
Junction Box)
Where local codes DO NOT permit connecting
the
appliance-grounding
conductor
to the neutral
(white)
wire, or if connecting
to 4-wire
electrical
system (see
Figure 6):
1.
Be sure that no power is supplied on the cable from
residence.
2.
Follow instructions on previous page for Four Conductor
Wire Connection to Range (Fig. 4).
3.
In the circuit breaker, fuse box or junction
box (Fig. 6):
a) Connect the white appliance cable wire to the neutral
(white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to
the grounding wire of the circuit breaker, fuse box or
junction box.
Cable from Residence
Green (or Bare
,,--_
I
Copper) Wire •
J
-'7
I:
White Wire
Black
_"--({-,._v
d_
Wires7
Green (or Bare /k___),_
" _
_
|
Copper) Wi
__
"_-- White Wire
Junction
Fi_J
""_U.L.-listed
Conduit
BOX
_"--J
*_-_
Connector (or CSA
Cable from
listed)
Appliance
NOTE: Be sure to remove the
supplied grounding strap.
>"
Figure 6 -4-Wire
Electrical
System
(Example:
Junction
Box)
4