Summary of Contents for Oase AquaMax Eco Titanium 31000
Page 1
AquaMax Eco Titanium 31000, 51000, 81000 Gebrauchsanleitung Használati útmutató Operating instructions Instrukcja użytkowania Notice d'emploi Návod k použití Gebruiksaanwijzing Návod na použitie Instrucciones de uso Navodila za uporabo Instruções de uso Uputa o upotrebi Istruzioni d'uso Instrucţiuni de folosinţă Brugsanvisning Упътване...
Page 5
Original manual. WARNING WARNING Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution. This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way...
• Only use original spare parts and accessories. • Route lines in such a way that they are protected from damage and do not present a tripping hazard. • Should problems occur, please contact the authorised customer service or OASE.
EGC- • • • EGC connection Connection for the OASE Eco Control or for integration in an EGC network. EGC- Important: Moisture in the EGC connection will damage the pump. • Always close the connection (with a protective cap or the EGC plug).
Page 8
SFC, the pump permanently operates at maximum throughput. The seasonal flow control does not function when the pump is installed on land (dry installation). If a skimmer, satellite filter or Oase InScenio control unit is used, we recommend deactivating the SFC function depending on the unit.
Secure the suction socket/pressure socket with a hand guard if no pipe is con- nected. The hand guard is available as an accessory (AquaMax Eco Titanium 31000: 48597, AquaMax Eco Titanium 51000, 81000: 73658). Place the pump in a pump chamber and secure access to the pump chamber (use a ...
Page 10
B, D • Ensure that the power cables and mains sockets are at least 2 m from the water. • For installation of the pump in a pump chamber (recommended): – For a swimming pond or pool frequented by swimming people, install the pump chamber at least 2 m from the water.
Page 11
Turning the pump casing to achieve a different position NOTE If the pump housing jams when it is removed and pushes against the impeller unit, this will damage the impeller unit. Position the pump vertically before removing the pump housing. This ensures that ...
Page 12
• The control unit Eco Control (47673) is available as an accessory for Eco Expert pumps. • Connect the OASE Eco Control system to EGC-IN on the pump. For information on connection and operation, refer to the operating manual of the OASE Eco Control system.
Page 13
• If the pump is integrated in an EGC network, connecting Eco Control is not possi- ble. For information on connection and operation, refer to the operating manual of the OASE InScenio FM-Master EGC or InScenio EGC Controller system. EGC0009 EGC0003...
• Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the guarantee. • Recommended cleaning agent for removing stubborn limescale deposits: – Pump cleaning agent PumpClean from OASE. – Vinegar- and chlorine-free household cleaning agent. • After cleaning, thoroughly rinse all parts in clean water.
Page 15
Changing the bearing requires specialist knowledge and tools. Have the bearing changed by the OASE specialist dealer or send the pump to OASE. NOTE If the pump housing jams when it is removed and pushes against the impeller unit, this will damage the impeller unit.
Page 17
AMX0102 Storage/winter protection The unit is not frost-proof and has to be removed and put into storage if minus tem- peratures are expected. How to correctly store the unit: • Thoroughly clean the unit and renew any damaged parts. • Store the pump submerged and in a frost-free environment. •...
Page 18
Malfunction remedy Malfunction Possible cause Remedy • Check the mains voltage. Pump does not start No mains voltage • Check supply lines. • Switch on the pump. Pump does not Excessively soiled water Clean the pump. The pump automat- transport fluid ically switches on again once the mo- tor has cooled down.
Technical data Unit data Description AquaMax Eco Titanium 31000 51000 81000 Connection voltage V AC 220 … 240 220 … 240 220 … 240 Mains frequency 50/60 50/60 50/60 Power consumption 35 … 170 70 … 320 100 … 730 Control using Inlet Connection thread...
Wear parts • Impeller unit • Bearing in the motor block Disposal NOTE Do not dispose of this unit with household waste. Dispose of the unit by using the return system provided for this purpose. Render the unit unusable by cutting the cables. ...
Need help?
Do you have a question about the AquaMax Eco Titanium 31000 and is the answer not in the manual?