Output Terminals - Fisher SRC-850A Instruction Manual

Sanyo fisher co. instruction manual video cassette recorder src-850a
Table of Contents

Advertisement

OUTPUT TERMINALS

TAPE END (SERIES) OUT Terminal
œ During recording, when the end of the tape is reached
or when the tape counter reading indicates 8 hours,
the output becomes 0V (Low). During autorepeat
recording, the output becomes 0 V (Low) for about 2
seconds only.
œ To reset the output, press the STOP or EJECT button.
TAPE END OUT Terminal Output Setting
1
Press the MENU button to display the MAIN MENU.
2
Press the l (or j) button to select the
"6.ALARM/SERIES REC SET" line, then press the
ENTER button.
ø The (ALARM/SERIES REC SET) menu
appears.
<ALARM/SERIES@REC@SET>
*ALARM@SET
@@MODE@@@@@@@@@@@Y
@@DURATION@@@@@@@20S
*SERIES@REC@@@@@@N
*TAPE@END@OUT@@@@8:00
3
Press the l (or j) button until the "TAPE END OUT"
setting is highlighted, then press the ENTER button.
4
Press the l (or j) button to select the desired
mode, then press the ENTER button.
8:00 . . . . . . . The output becomes 0 V (Low)
when the tape counter reaches
"8:00:00" and/or when the tape
reaches the end.
END . . . . . . . The output becomes 0 V (Low)
when the tape reaches the end.
NOTES:
œ If the "SERIES REC" is set to "Y" in the
(ALARM/SERIES REC SET) menu, the output
becomes 0 V (Low) for about 2 seconds when the
counter reaches "8:00:00", even if the "TAPE
END OUT" is set to "END".
œ If the "SERIES REC" is set to "Y" in the
(ALARM/SERIES REC SET) menu, the output
becomes 0 V (Low) until 5 minutes have passed
after the tape reaches the end.
5
Press the MENU EXIT button.
COM Terminal
œ Common GND (ground) terminal when connecting
other terminals to external devices.
34
English

Advertisement

Table of Contents
loading

Table of Contents