Setting For Rs-485 Use - Fisher SRC-850A Instruction Manual

Sanyo fisher co. instruction manual video cassette recorder src-850a
Table of Contents

Advertisement

SETTING FOR RS-485 USE

The RS-485 interface can be used to operate the VCR
using a SANYO brand system controller.
NOTE:
œ Refer to the instruction manual for the system
controller.
Setting the Address, Data Transfer
Speed and Termination
œ Make this setting without a cassette tape inserted.
1
Press the PLAY button for 3 seconds or more.
ø "Ad" and the address number appear on the
digital display.
2
Press the l (or j) button to set the VCR address
(from 000 to 127).
ø The address set appears on the digital display.
3
Press the ENTER button.
4
Press the l (or j) button to set the data transfer
speed (19200, 2400, 4800, 9600).
ø The data transfer speed set appears on the
digital display.
5
When finished, press the PLAY button.
6
Move the shorting bar of the RS-485 interface board
to change the TERMINATION setting.
ON (Terminated)
SHORT FOR
TERMINATION.
COM
NOTE:
œ When the MENU RESET button is pressed, the
setting appearing on the digital display is reset to the
default setting.
OFF (Not terminated)
SHORT FOR
TERMINATION.
COM
32
Settings when using RS-485
1
Press the MENU button to display the MAIN MENU.
2
Press the l (or j) button to select the "8.OTHERS"
line, then press the ENTER button.
ø The (OTHERS) menu appears.
<OTHERS>
*ALARM@LOG
*POWER@FAILURE/DEW
*RS-485@SET
@@STATUS@INFO.@@@Y
@@ALARM@INFO.@@@@Y
3
Press the l (or j) button until the "STATUS INFO."
setting is highlighted, then press the ENTER button.
4
Press the l (or j) button to set the "STATUS
INFO." setting, then press the ENTER button.
Y. . . . . . . . . . The VCR status information is
output at the RS-485 connector.
N. . . . . . . . . . The status information is not
output at the RS-485 connector.
5
Press the l (or j) button until the "ALARM INFO."
setting is highlighted, then press the ENTER button.
6
Press the l (or j) button to set the "ALARM INFO."
setting, then press the ENTER button.
Y. . . . . . . . . . The VCR alarm information (alarm
recording start and stop) and
video loss information are output
at the RS-485 connector.
N. . . . . . . . . . The VCR alarm information (alarm
recording start and stop) and
video loss information are not
output at the RS-485 connector.
7
Press the MENU EXIT button.
NOTE:
œ When a warning state (non-recording or mechanical
problem) occurs, the warning state is output from the
RS-485 connector. However, non-recording warning
states are not output if "NON REC" is set to "N" in the
(WARNING OUT/EJECT SET) menu.
English

Advertisement