Fiessler TLCT Operating Manual page 6

Type 2 safety light curtains
Table of Contents

Advertisement

FIESSLER
E L E K T R O N I K
LEDs and displays
Display on interruption of a light beam
If one or more light beams are interrupted, the number of the
uppermost interrupted beam (as seen from the connecting plug) is
displayed.
On light grids comprising more than 99 light beams, the right-hand
decimal point also shines if the 122
instance. If a light beam numbered higher than 200 is interrupted,
both decimal points shine.
If the synchronous eye is interrupted (1
the connecting plug), "0 0" flashes on the display.
Fiessler Elektronik GmbH & Co. KG
Kastellstr. 9
D 73734 Esslingen
System description
1
The LEDs and display on the receiver indicate the current operating status.
Outputs (OSSDs) active ................ green LED comes on when the outputs are energized.
Outputs (OSSDs) inactive .............. red LED comes on when the outputs are de-energized.
- Indication of operating mode ...... for about 2 seconds during power-on.
- Indication of the uppermost ........
interrupted light
- Error diagnosis ............................
Adjustment aid and light reserves .. red LED comes on when light reserves have dropped.
Restart interlock ............................ in the operating mode with restart interlock, the yellow
nd
beam is interrupted, for
st
light beam as seen from
BA - TLCT /
BA - TLCT / ICT_1129
see below
refer to the chapter on error diagnosis
LED comes on when the protective field is clear and
the start button is ready for operation.
Phone: +49 / 711 / 91 96 97-0 Internet: http://www.fiessler.de
6
Fax:
+49 / 711 / 91 96 97-50 E-mail: info@fiessler.de
Table of Contents
LEDs and displays
1.4
23rd light beam is
interrupted.
122nd light beam is
interrupted.
1st light beam is
interrupted.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ilct

Table of Contents