Fiessler TLCT Operating Manual page 22

Type 2 safety light curtains
Table of Contents

Advertisement

FIESSLER
E L E K T R O N I K
Connector for the TLCTE receiver
Pin 1 / white:
3
2
8
Pin 2 / brown:
Pin 3 / green:
4
1
Pin 4 / yellow:
Pin 5 / grey:
7
5
Pin 6 / pink:
Pin 7 / blue:
6
Pin 8 / red/shield:-
Connection with restart interlock / with contactor control (EDM)
1 / white:
Start
2 / brown:
+UB
4 / yellow:
EDM
5 / grey:
OSSD1
6 / pink:
OSSD2
7 / blue:
-UB
Connection without restart interlock / without contactor control (EDM))
1 / white:
Start
2 / brown:
+UB
4 / yellow:
EDM
5 / grey:
OSSD1
6 / pink:
OSSD2
7 / blue:
-UB
Connector for the TLCTS transmitter
Pin 1 / brown:
2
Pin 2 / white:
Pin 3 / blue:
3
1
Pin 4 / black:
4
Fiessler Elektronik GmbH & Co. KG
Kastellstr. 9
D 73734 Esslingen
Electrical connection
3
Start
Enabling of start with restart interlock, max. 24V DC +- 20%
+UB
+24V DC +-20% SELV, PELV
-
EDM
Contactor control, max. 24V DC +- 20%
OSSD1 Safety output 1, max. 500 mA
OSSD2 Safety output 2, max. 500 mA
-UB
0V
Enabling of start /
k2
k1
Contactor control
K1
K2
K1
K2
+UB
+24V DC +20%-15% SELV, PELV
Functional earth
-UB
0V
-
BA - TLCT / ICT_1129
Connection of the transmitter and receiver
3.1 - 3.4
Observe the safety notes
+24V DC +-20%
X
X
X
X
0V
+24V DC +-20%
X
X
X
X
0V
Phone: +49 / 711 / 91 96 97-0 Internet: http://www.fiessler.de
22
Fax:
+49 / 711 / 91 96 97-50 E-mail: info@fiessler.de
Table of Contents
on Page 23!
X: To interrupt hazardous
X
movement.
k1
If a hazardous movement
enters the sphere of
k2
contactors K1 and K2, the
normally open contacts of K1
and K2 must be connected in
X
series.
X: To interrupt hazardous
X
movement.
k1
If a hazardous movement
enters the sphere of
k2
contactors K1 and K2, the
normally open contacts of K1
and K2 must be connected in
X
series.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ilct