Summary of Contents for Envirovent ECO dMEV LC

  • Page 1 ECO dMEV LC...
  • Page 5 ECO dMEV LC N 230Vac 50/60Hz KIT ECO dMEV LC + CT-17/18 +17V +17V LS’ CT-17/18 230Vac 50/60Hz Fig.3...
  • Page 6 ECO dMEV LC 230Vac 50/60Hz 230Vac 50/60Hz KIT ECO dMEV LC + CT-17/18 +17V +17V LS’ CT-17/18 230Vac 230Vac 50/60Hz 50/60Hz Fig.4...
  • Page 7 ECO dMEV LC 230Vac 50/60Hz KIT ECO dMEV LC + CT-17/18 +17V +17V LS’ CT-17/18 230Vac 50/60Hz Fig.5...
  • Page 8 7. Potentiometer for speed adjustment reduced physical, sen- 8. Air fi lter sory or mental capabi- The ECO dMEV LC is suitable for wall lities or lack of expe- or ceiling mounting and can either ex- tract directly to the outside or via an rience and knowledge individual ducting system (see Fig.
  • Page 9 (7) placed on the electronic PCB (fi g.1b). ELECTRICAL CONNECTION The ECO dMEV LC is an extractor de- Please commission the fan at 9l/s or signed for a single phase supply, with above to meet SAP requirements.
  • Page 10 an external switch or light switch. When the switch is closed, the fan runs at full speed until the switch opens again (light off): Factory setting: 1 minute Fig.4a- Wiring diagram to boost the fan with the light switch. 1. Continuous operation: The timer Fig.4b- Wiring diagram to boost allows the fan to continue to ope- the fan with a separate switch...
  • Page 11: Specific Recommendations

    humidity) and with a timer, adjustable (fi g.4b), when the humidity level in between 1 and 30 minutes. the room is lower than the selec- ted level. In this case, the extrac- The selection of desired humidity le- tor operates in high speed for the vel is done with the dip-switches 4 selected period set on the timer and 5: setting between 60, 70, 80 and...
  • Page 12 supply with only two wires (fi g.3). The To adjust the pre-set time for interval humidity sensor causes the extractor function, use the dip-switches 2 and 3. to operate automatically when the humidity level in the room is higher than the set level. The extractor will stop automatically when the humidity drops below the selected level (-5% or +10%) and after the selected period...
  • Page 13 ECO DMEV HTP LC 2. Intermittent operation: The unit starts automatically when ECO dMEV LC version similar to HT a movement is detected and the model, fi tted with an internal pull unit continues to operate for the cord switch to operate the boost when...
  • Page 14 If your device is also labeled with this symbol, please take it to the nearest Waste Manage- ment Plant at the end of its servicable life. EnviroVent reserves the right to alter speci- fi cations without notice.
  • Page 15: Warranty

    WARRANTY The ECO dMEV LC products are covered by a two year warranty, subject to the specifi ed maintenance stated within this booklet. If your fan has been supplied and installed by EnviroVent it is covered with a full parts and labour warranty. If you detect a fault, please con- tact us on 0345 27 27 810.
  • Page 16 EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 info@envirovent.com www.envirovent.com Ref. 9023045204...