Storage - Packaging - Transportation - Schaudt LAS 1218-2 Manual

Table of Contents

Advertisement

Available languages

Available languages

Instruction Manual and Installation Instructions LAS 1218-2
Battery charging via
mains connector
Battery charging of the
starter battery
Operation as
power supply unit
2.5.3
Operating temperature
Storage temperature
Humidity
18
Living area battery
Charging curve
Final charging voltage
Charge current
Voltage for float charge
New charge cycle,
Switchover to main charging
Solar
charging
V
Main charge
I
14,3
13,8
Fig. 9
Example of the charge voltage behaviour with the LAS 1218-2 battery charger
I
Main charge with maximum 18 A charging current, electronically limi-
ted, up to final charging voltage. Start of charge also for totally dischar-
ged batteries.
Uo Automatic changeover to full charge with constant 14.3 V. The duration
of the full charge phase depends on the type of battery and is configu-
red on the device: Lead-acid batteries, 4 hour, lead-gel batteries, 16
hours.
U
Automatic changeover to trickle charge with constant 13.8V. In the
trickle charge phase, the voltage at the output of the charging module
is constant. The battery is now fully, or virtually fully, charged.
Start of a new charging cycle by switching over to main charge, if the battery
voltage falls below 13.8 V for more than 5 seconds when loaded. Start of
charge also for totally discharged batteries.
For mains operation, the starter battery is also charged (with maximum
charge current of 3A). The final charge voltage is 14.1 V.
Output current 18 A, connection of a battery not required
Output voltage 14.3V/13.8V,
suitable for 12V consumers, smoothed DC voltage
Environmental parameters
-20 °C to +45 °C
-20 °C to +70 °C
Operation in dry environment only
CE
CE mark
2.6

Storage - Packaging - Transportation

Only transport and store the battery charger if the packing is suitable and
ambient conditions are dry.
No part of this manual may be reproduced, translated or copied without ex-
E
press written permission.
IUoU
14.3 V
18 A in the entire mains voltage range,
electronically limited, minus the
charge current into the vehicle battery
13.8 V with automatic switchover
with battery voltage below 13.8 V
with approx. 5 seconds delay
Full charge
Float charge
Uo
4 h with lead acid
16 h with lead gel
Date: 06.11.2014
U
Time
810.523 BA / EN

Hide quick links:

Advertisement

Table of Contents
loading