  • Page 1 IRS-FB432A/ IRS-FB462A Series Dual-spectrum Network Bullet Camera Quick Start Guide V1.0.0 Yantai IRay Technology Co., Ltd.
  • Page 2 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China ©IRay Technology Co.,Ltd. 2020 Reserve all the right. All in this manual including texts, pictures, diagrams and other contents belong to IRay Technology Co.,Ltd (Hereinafter referred to as “Our company”or “IRay Photoelectric”). Without the written permission, no one shall copy, photocopy, translate or disseminate all or part of this manual.
  • Page 3: Important Safety Instructions

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Important Safety Instructions In order to avoid danger or property damage, the following right usage rules are for you to follow. Please read the instructions carefully and rigorously follow the instructions before usage.
  • Page 4 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China supply requirements should comply with those on the device labels.) ⚫ In order to make emergency power off when necessary, please install power-off equipment which is easy to use when installing the wires. ⚫...
  • Page 5 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China materials of the same quality. ⚫ Please do not press, vibrate violently or soak the camera during transportation, storage or installation. ⚫ It is advised to use the camera with lighting protector. ⚫...
  • Page 6: Table Of Contents

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Table of Contents Important Safety Instructions ..............II 1. Introduction ..................1 1.1 Product Information ................1 1.2 Product Features ................... 1 1.3 Product Appearance ................2 1.4 Cable Instructions .................
  • Page 7: Introduction

    1.2 Product Features ⚫The latest InfiRay® 12μm IR thermal imaging detector, advanced IR vision algorithm, more distant and clearer image. ⚫Function of front-end independent temperature measuring; installed with professional temperature measuring analysis tools and multiple linkage alarm rules;...
  • Page 8: Product Appearance

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China ⚫One-piece shell, with outdoor protection class IP66. ⚫ONVIF standard interface protocol supported, available SDK, secondary development and third-party platform connection supported. 1.3 Product Appearance Figure 1.1 Appearance and Interface for Dual-spectrum Bullet Camera 1.4 Cable Instructions The cable includes interfaces for power, alarm, audio, RS-485, network, video, etc.
  • Page 9 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Figure1.2 Cable Instructions ⚫ Video interface(VIDEO): output analog video signal. The device can output images if connected to TV monitor. ⚫ Audio Output(AUDIO OUT): output audio signal to speakers and other equipment for sound output.
  • Page 10: Alarm Interface Wiring Instructions

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China ⚫ Power connector(DC12V): support DC 12V DC power supply. Please connect the positive and negative poles of the power supply correctly. ⚫ Network Interface(LAN): network signal output and connected with standard Ethernet cable.
  • Page 11: Installation

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Figure 1.3 Alarm Output Wiring Diagram 2. Installation 2.1 Pre-installation Instructions Before installation, please make sure that the equipment in the package is intact with all complete parts. ⚫...
  • Page 12: Monitoring Distance Recommendations

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China ⚫ Do not directly pull the cable at the back of the device when moving, otherwise it may affect the waterproof performance or cause wiring problems shown in the figure below.
  • Page 13 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Table 2.1 Monitoring Distance Recommendation(17μm Pixel) Focal length/mm Resolution/mrad 1 .753 1.308 0.895 0.680 0.486 Detection 1173 1714 2255 3157 distance(Vehicle)/m Detection 1029 distance(Human)/m Recognition distance(Vehicle)/m Recognition distance(Human)/m Identification...
  • Page 14: Installation Guide

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China ⚫ Assuming that it is clear, the visibility of the atmosphere is at a normal level, and there is no obvious fog or haze, the probability of reading the target at the specified distance is 50%.
  • Page 15 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Figure 2.2 Unscrew TF card Slot Cover Step 2 Insert the TF card slowly into the TF card slot in the direction indicated by the arrow. After you hear a "click", the installation is completed, as shown in the figure below.
  • Page 16 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China holes. According to the "A" marked on the sticker, open a Φ36 hole with "A" as the center of the circle for wiring. Figure 2.4 Install Sticker Step 2 Fix bullet camera Pass the tail wire of the device through the "A"...
  • Page 17 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Figure 2.6 Ceiling Mounting Step 3 Adjust the Monitoring Angle Use the equipped L-shaped hex key to loosen 1 lock nut near the device bracket respectively, adjust it to a predetermined position by turning or rotating, and tighten the lock nut, as shown in the figure below.
  • Page 18 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China The installation steps of the waterproof set for the network port are as follows. Step 1 Pass the network cable through the fastening nut and the main body of the waterproof set in turn.
  • Page 19: Operation Guide

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China 3. Operation Guide 3.1 Preparations 1. The default IP address of the device:192.168.1.19. 2. Subnet mask code is 255.255.255.0, The IP address of the device can be modified, for example, changing the device address to 192.168.1.194;...
  • Page 20 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Figure 3.1 Login Interface 2. Read the prompts on the web page carefully. If you need to install the control, please click the "Download and install the control" button, and then follow the prompts to successfully complete the installation of the control.
  • Page 21: Main Interface Description

    Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China below: Figure 3.2 Preview Interface 3.3 Main Interface Description Operations and configurations such as preview, video playback, and parameter setting can be performed on the main interface of the device. 1.
  • Page 22 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Appendix A Installation and Maintenance Lens Maintenance The lens surface is coated with anti-reflective coating. When it is stained with dust, grease, fingerprints, etc., harmful substances will generate, which will degrade its performance or cause scratches, mildew, etc.
  • Page 23 Yantai IRay Technology Co., Ltd. 11th Guiyang Street, YEDA Yantai 264006, P. R. China Appendix B Emissivity for Common Substance Substance Emissivity Temperature(℃) Water 0~100 0.95~0.98 Soil(dry) 0.92 Soil(wet) 0.95 Woods 0.962 Sand Sandstone 0.909~0.935 PVC plastics 0.93 Asphalt 0.967 Paint 0.92~0.94 Wallpaper...