DECALING (Periodical)
To ensure good appliance efficiency it is recommendable to
periodically decaled the heating element. The frequency of this
operation depends on the water hardness; proceed as follows:
• Switch off the power to the appliance.
• Empty the tank.
• Remove the electrical protection cover by undoing the fixing
screws.
• Disconnect the electrical wires from the respective terminals
and remove the thermostat.
Remove the thermostat from its housing.
• Remove the heating element with a suitable hexagon
spanner.
• Remove any scale and clean, taking care not to damage the
heating element armour.
When refitting, make sure:
• The heating element is correctly housed and that the seals
are correctly fitted.
• The thermostat is inserted in the housing of the heating
element, pushing all the way in but without any striking that
can damage it; make sure internal male/female contacts are
correctly inserted.
• Before reconnecting the power, fill the appliance (see the
relevant section) and check for any water leaks.
IMPORTANT: Repair and / or maintenance operations must
be carried only using original spare parts and by qualified
personal.
Before
disconnect the appliance from the power mains.
Non-professionals are not allowed to disassemble the
thermal switch to reset. Please contact prefessionals to
maintain. Otherwise our company will not take responsiblity
if any quality accident happens because of this.